Ultrasound Overestimates the Area of Necrosis during Radiofrequency Ablation in Porcine Livers

E. G. Santi, S. Lu, M. Milo, Redigo Aguilar, Hendra Nurjadin, Susanne Gosalvez-Pe, Stephen N. Wong
{"title":"Ultrasound Overestimates the Area of Necrosis during Radiofrequency Ablation in Porcine Livers","authors":"E. G. Santi, S. Lu, M. Milo, Redigo Aguilar, Hendra Nurjadin, Susanne Gosalvez-Pe, Stephen N. Wong","doi":"10.3860/pjim.v47i3.1653","DOIUrl":null,"url":null,"abstract":"Results: There was a trend for increased horizontal diameter for both ultrasound (RFA 6 mins=3.8+0.5cm vs. RFA 12 mins = 5.1+1.0cm; p = 0.079) and grossly (RFA 6mins = 2.7+0.27cm vs. RFA 12mins = 3.1+0.24cm; p = 0.068) with increased RFA duration from 6 to 12 minutes, which was not observed for the longitudinal diameter. Ultrasound consistently overestimated the actual necrotic diameter by 1.3+0.8cm (range = 0.4 to 3.6cm) (p = 0.01) whether RFA was performed for 6 (1.0+0.3cm) or 12 (1.8+1.2cm) minutes.","PeriodicalId":85270,"journal":{"name":"Philippine journal of internal medicine","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2010-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Philippine journal of internal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3860/pjim.v47i3.1653","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Results: There was a trend for increased horizontal diameter for both ultrasound (RFA 6 mins=3.8+0.5cm vs. RFA 12 mins = 5.1+1.0cm; p = 0.079) and grossly (RFA 6mins = 2.7+0.27cm vs. RFA 12mins = 3.1+0.24cm; p = 0.068) with increased RFA duration from 6 to 12 minutes, which was not observed for the longitudinal diameter. Ultrasound consistently overestimated the actual necrotic diameter by 1.3+0.8cm (range = 0.4 to 3.6cm) (p = 0.01) whether RFA was performed for 6 (1.0+0.3cm) or 12 (1.8+1.2cm) minutes.
超声高估猪肝射频消融过程中的坏死面积
结果:两种超声均有水平直径增大的趋势(RFA 6 min =3.8+0.5cm vs RFA 12 min = 5.1+1.0cm);p = 0.079)和粗(RFA 6min = 2.7+0.27cm vs RFA 12min = 3.1+0.24cm;p = 0.068), RFA持续时间从6分钟增加到12分钟,而纵向直径没有观察到这一点。无论RFA时间为6 (1.0+0.3cm)还是12 (1.8+1.2cm) min,超声对实际坏死直径的高估均为1.3+0.8cm(范围= 0.4 ~ 3.6cm) (p = 0.01)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书