Evaluation of Predictive Value of Uterine Artery Doppler Indices versus Histopathology Sampling in Detection of Abnormal Uterine Bleeding in Intrauterine Contraceptive Device Users

M. Gobran, S. Hanafy, W. M. Elnagar, A. Ahmed, Amr Ahmed Abdelrhman, M. Lashin, Y. Saraya, E. A. E. Fattah, K. F. Helal, Hebatullah Abulkhair, A. Barry, M. Ramadan
{"title":"Evaluation of Predictive Value of Uterine Artery Doppler Indices versus Histopathology Sampling in Detection of Abnormal Uterine Bleeding in Intrauterine Contraceptive Device Users","authors":"M. Gobran, S. Hanafy, W. M. Elnagar, A. Ahmed, Amr Ahmed Abdelrhman, M. Lashin, Y. Saraya, E. A. E. Fattah, K. F. Helal, Hebatullah Abulkhair, A. Barry, M. Ramadan","doi":"10.35248/2090-7214.21.18.382","DOIUrl":null,"url":null,"abstract":"Background: Contraceptive intrauterine device (IUD) is a successful method of contraception that has been used for more than 30 years. However, it is associated with excessive uterine bleeding, that might cause iron deficiency anaemia, making CIUD use inconvenient for many women especially those with severe menstruation. Objective: The objective of our study was to evaluate the correlation between abnormal uterine bleeding in IUD with endometrial sampling. Methods: Study included 120 women from the obstetrics and gynaecology departments of Zagazig University Hospitals, divided into three groups: Group I included 40 women who used intrauterine coipper (TCu-380A) and complained of menorrhagia or menometrorrhagia. Group II included 40 womenusing CIUD and not complaining of abnormal uterine bleeding. Group III included 40 women complaining of vaginal discharge or requesting CIUD insertion, and not complaining of abnormal uterine bleeding as a control group. Results: PI and RI were significantly lower in IUD-induced irregular bleeding than in IUD-induced women who did not complain of abnormal vaginal bleeding. Conclusion: Endometrial biopsy has no role in predicting the abnormal uterine bleeding cause. Transvaginal ultrasonography findings can be efficiently used to classify women at risk of experiencing excessive uterine bleeding following CIUD insertion and to make a preliminary diagnosis, thus, notify the pathologists.","PeriodicalId":92765,"journal":{"name":"Clinics in mother and child health","volume":"102 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in mother and child health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35248/2090-7214.21.18.382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Contraceptive intrauterine device (IUD) is a successful method of contraception that has been used for more than 30 years. However, it is associated with excessive uterine bleeding, that might cause iron deficiency anaemia, making CIUD use inconvenient for many women especially those with severe menstruation. Objective: The objective of our study was to evaluate the correlation between abnormal uterine bleeding in IUD with endometrial sampling. Methods: Study included 120 women from the obstetrics and gynaecology departments of Zagazig University Hospitals, divided into three groups: Group I included 40 women who used intrauterine coipper (TCu-380A) and complained of menorrhagia or menometrorrhagia. Group II included 40 womenusing CIUD and not complaining of abnormal uterine bleeding. Group III included 40 women complaining of vaginal discharge or requesting CIUD insertion, and not complaining of abnormal uterine bleeding as a control group. Results: PI and RI were significantly lower in IUD-induced irregular bleeding than in IUD-induced women who did not complain of abnormal vaginal bleeding. Conclusion: Endometrial biopsy has no role in predicting the abnormal uterine bleeding cause. Transvaginal ultrasonography findings can be efficiently used to classify women at risk of experiencing excessive uterine bleeding following CIUD insertion and to make a preliminary diagnosis, thus, notify the pathologists.
子宫动脉多普勒指数与组织病理学抽样对宫内节育器使用者异常子宫出血的预测价值评价
背景:宫内节育器(IUD)是一种成功的避孕方法,已经使用了30多年。然而,它与子宫过度出血有关,这可能导致缺铁性贫血,使许多妇女使用CIUD不方便,特别是那些月经严重的妇女。目的:探讨宫内节育器内异常子宫出血与子宫内膜取样的关系。方法:选取来自扎加齐格大学附属医院妇产科的120名妇女,分为三组:第一组40名使用宫内铜器(TCu-380A)并主诉月经过多或月经过多的妇女。第二组包括40名使用节育器且无子宫异常出血主诉的妇女。第三组包括40名妇女,她们抱怨阴道分泌物或要求插入宫内节育器,而对照组没有抱怨子宫异常出血。结果:宫内节育器引起的不规则出血的PI和RI明显低于没有阴道异常出血的宫内节育器引起的妇女。结论:子宫内膜活检对子宫异常出血的病因无预测作用。经阴道超声检查结果可以有效地用于分类妇女在宫内节育器插入后经历子宫过度出血的风险,并作出初步诊断,从而通知病理学家。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信