Alteração refracional após capsulotomia posterior com laser Nd:YAG

Q4 Medicine
Bruno Hirt, Marcos Bortoluzzi Worma, L. Wojcik, Bruna Schmittt de Lacerda, Luciane Bugman Moreira, P. Ferenczy
{"title":"Alteração refracional após capsulotomia posterior com laser Nd:YAG","authors":"Bruno Hirt, Marcos Bortoluzzi Worma, L. Wojcik, Bruna Schmittt de Lacerda, Luciane Bugman Moreira, P. Ferenczy","doi":"10.37039/1982.8551.20220006","DOIUrl":null,"url":null,"abstract":"Objective: To identify if there is a significant change on refraction after Nd:YAG laser posterior capsulotomy in pseudophakic eyes. Methods: A retrospective study with analysis of medical records of patients treated at a hospital, with diagnosis of opacification of posterior lens capsule treated with Nd:YAG laser posterior capsulotomy, from October 2019 to March 2021. The comparison of refraction before and after the procedure was performed by calculating the spherical equivalent. Changes in visual acuity (VA), measured by LogMAR, were also evaluated. Results: A total of 90 medical records (140 eyes) of patients submitted to Nd:YAG laser posterior capsulotomy were analysed. The mean pre-procedure spherical equivalent was -0.07±0.89D, minimum of -3.0D and maximum of +2.5D, median (interquartile range) of 0.0D (-0.50D to +0.375D). The postprocedure mean was -0.18±0.86D, minimum of -3.5D and maximum of +2.25D, median (interquartile range) of -0.125D (-0.50D to 0.0D), with p <0.0082. Of the 140 eyes, 66 underwent myopia and 37 hyperopia, the mean change in the general spherical equivalent was -0.12±0.51D, minimum -2.50D and maximum +1.25D, median (interquartile range) of 0.0D (-0.375D to +0.125D). When comparing the difference between the spherical equivalent before and after the procedure of the group of eyes that underwent myopia (n=66) or hyperopia (n=37), separately, both obtained p<0.0001. When comparing all eyes that suffered any change on refraction (n=103), the p value was 0.008. The mean pre-procedure visual acuity was 0.23±0.32, minimum of 0.0 and maximum of 2.3. After the procedure, the mean was 0.06±0.13, minimum of -0.12 and maximum of 0.7, p<0.0001. Conclusion: Nd:YAG laser posterior capsulotomy significantly improved visual acuity of patients in this study; however, it also led to a significant change on refraction after the procedure, both for myopization, which was more frequent, and for hyperopization.","PeriodicalId":49619,"journal":{"name":"Revista Brasileira De Oftalmologia","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira De Oftalmologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37039/1982.8551.20220006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To identify if there is a significant change on refraction after Nd:YAG laser posterior capsulotomy in pseudophakic eyes. Methods: A retrospective study with analysis of medical records of patients treated at a hospital, with diagnosis of opacification of posterior lens capsule treated with Nd:YAG laser posterior capsulotomy, from October 2019 to March 2021. The comparison of refraction before and after the procedure was performed by calculating the spherical equivalent. Changes in visual acuity (VA), measured by LogMAR, were also evaluated. Results: A total of 90 medical records (140 eyes) of patients submitted to Nd:YAG laser posterior capsulotomy were analysed. The mean pre-procedure spherical equivalent was -0.07±0.89D, minimum of -3.0D and maximum of +2.5D, median (interquartile range) of 0.0D (-0.50D to +0.375D). The postprocedure mean was -0.18±0.86D, minimum of -3.5D and maximum of +2.25D, median (interquartile range) of -0.125D (-0.50D to 0.0D), with p <0.0082. Of the 140 eyes, 66 underwent myopia and 37 hyperopia, the mean change in the general spherical equivalent was -0.12±0.51D, minimum -2.50D and maximum +1.25D, median (interquartile range) of 0.0D (-0.375D to +0.125D). When comparing the difference between the spherical equivalent before and after the procedure of the group of eyes that underwent myopia (n=66) or hyperopia (n=37), separately, both obtained p<0.0001. When comparing all eyes that suffered any change on refraction (n=103), the p value was 0.008. The mean pre-procedure visual acuity was 0.23±0.32, minimum of 0.0 and maximum of 2.3. After the procedure, the mean was 0.06±0.13, minimum of -0.12 and maximum of 0.7, p<0.0001. Conclusion: Nd:YAG laser posterior capsulotomy significantly improved visual acuity of patients in this study; however, it also led to a significant change on refraction after the procedure, both for myopization, which was more frequent, and for hyperopization.
Nd:YAG激光包膜切开术后的屈光变化
目的:探讨Nd:YAG激光后囊膜切开术对假性晶状眼屈光是否有明显改变。方法:回顾性分析2019年10月至2021年3月在某医院接受Nd:YAG激光后囊膜切开术治疗的诊断为晶状体后囊膜混浊的患者病历。通过计算球面等效,比较了操作前后的折射率。用LogMAR测量的视力变化(VA)也进行了评估。结果:对Nd:YAG激光后囊膜切开术患者90例(140眼)病历进行分析。平均术前球形当量为-0.07±0.89D,最小值为-3.0D,最大值为+2.5D,中位数(四分位数范围)为0.0D (-0.50D至+0.375D)。术后平均为-0.18±0.86D,最小为-3.5D,最大为+2.25D,中位数(四分位数间距)为-0.125D (-0.50D ~ 0.0D), p <0.0082。140只眼中,近视66只,远视37只,一般球等效变化平均值为-0.12±0.51D,最小值为-2.50D,最大值为+1.25D,中位数(四分位数间距)为0.0D (-0.375D ~ +0.125D)。分别比较近视组(n=66)和远视组(n=37)手术前后球当量的差异,p<0.0001。当比较所有发生任何折射变化的眼睛时(n=103), p值为0.008。术前平均视力为0.23±0.32,最小为0.0,最大为2.3。手术后,平均值为0.06±0.13,最小值为-0.12,最大值为0.7,p<0.0001。结论:Nd:YAG激光后囊膜切开术可显著提高患者的视力;然而,它也导致手术后屈光的显著变化,无论是近视,这是更频繁的,还是远视。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
43
审稿时长
6-12 weeks
期刊介绍: A Revista Brasileira de Oftalmologia (Rev Bras Oftalmol.) - ISSN 0034-7280, publicação científica da Sociedade Brasileira de Oftalmologia, se propõe a divulgar artigos que contribuam para o aperfeiçoamento e o desenvolvimento da prática, da pesquisa e do ensino da Oftalmologia e de especialidades afins. Todos os manuscritos, após aprovação pelos Editores serão avaliados por dois ou três revisores qualificados (peer review), sendo o anonimato garantido em todo o processo de julgamento.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信