Micro V Doppler assessment of testicular blood supply in the pediatric age population: may reduce the need for senior guidance in the evaluation of prepubertal torsion

S. Şimşek, Mehmet Karagülle, Z. Arslan, Süleyman Öncü, M. Öncü, Ahmet Tan Cimilli
{"title":"Micro V Doppler assessment of testicular blood supply in the pediatric age population: may reduce the need for senior guidance in the evaluation of prepubertal torsion","authors":"S. Şimşek, Mehmet Karagülle, Z. Arslan, Süleyman Öncü, M. Öncü, Ahmet Tan Cimilli","doi":"10.33719/yud.2022;17-2-1030239","DOIUrl":null,"url":null,"abstract":"Objective: We evaluated the testis vascularity in pediatric population with MicroV Doppler (MVD) and Q pack examination and to detect differences between a limited experience and a experienced senior radiologists. The inter-observer agreement in MVD and Q pack examination is evaluated. We also compared MVD and Q pack examination with color and power Doppler in demonstrating testicular blood supply in children. Material and Methods: 114 testis (between the ages of 4-14) were included in the study. Testicular microvessel structure was examined by using color, power, MicroV Doppler and Q-pack examination techniques. A grouping system was created for color, Power and MicroV Doppler to score the vascularity of the testicular parenchyma visually. Results: In our study, we confirmed the presence of testicular blood flow with MVD in all children. We found that there was no significant difference between the observers in color, power Doppler and MVD and the consistency value was higher in MVD compared to color and power Doppler. We observed a significant positive correlation between Q-pack values and patient age. Q-pac values obtained from this study increased with age. The lack of statistically significant bias indicates that the method is useful. Conclusion: MVD is a reproducible method since there is no significant interobserver variability and can easily detect acute scrotal pathologies such as prepubertal torsion for the less experienced radiologists in the early years of working life. Thus, the need for senior guidance accompanying radiology resident in the evaluation of emergency cases in children may decrease. Keywords: blood supply, micro V doppler, pediatric age population","PeriodicalId":33828,"journal":{"name":"Yeni Uroloji Dergisi","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Yeni Uroloji Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33719/yud.2022;17-2-1030239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: We evaluated the testis vascularity in pediatric population with MicroV Doppler (MVD) and Q pack examination and to detect differences between a limited experience and a experienced senior radiologists. The inter-observer agreement in MVD and Q pack examination is evaluated. We also compared MVD and Q pack examination with color and power Doppler in demonstrating testicular blood supply in children. Material and Methods: 114 testis (between the ages of 4-14) were included in the study. Testicular microvessel structure was examined by using color, power, MicroV Doppler and Q-pack examination techniques. A grouping system was created for color, Power and MicroV Doppler to score the vascularity of the testicular parenchyma visually. Results: In our study, we confirmed the presence of testicular blood flow with MVD in all children. We found that there was no significant difference between the observers in color, power Doppler and MVD and the consistency value was higher in MVD compared to color and power Doppler. We observed a significant positive correlation between Q-pack values and patient age. Q-pac values obtained from this study increased with age. The lack of statistically significant bias indicates that the method is useful. Conclusion: MVD is a reproducible method since there is no significant interobserver variability and can easily detect acute scrotal pathologies such as prepubertal torsion for the less experienced radiologists in the early years of working life. Thus, the need for senior guidance accompanying radiology resident in the evaluation of emergency cases in children may decrease. Keywords: blood supply, micro V doppler, pediatric age population
儿童年龄人群睾丸血供的微V多普勒评估:可能减少对青春期前扭转评估的高级指导的需要
目的:应用微多普勒(MicroV Doppler, MVD)和Q包检查对小儿睾丸血管状况进行评估,并探讨经验有限的资深放射科医师与经验丰富的资深放射科医师的差异。评价了MVD和Q包检验中观察者间的一致性。我们还比较了MVD和Q包检查与彩色和功率多普勒显示儿童睾丸血供。材料与方法:114例睾丸(年龄在4-14岁之间)纳入研究。采用彩色、功率、MicroV多普勒、Q-pack等技术检查睾丸微血管结构。建立了彩色、功率和微多普勒分组系统,对睾丸实质的血管性进行视觉评分。结果:在我们的研究中,我们证实了所有儿童都存在MVD的睾丸血流。我们发现观察者在颜色、功率多普勒和MVD上没有显著差异,MVD的一致性值高于颜色和功率多普勒。我们观察到Q-pack值与患者年龄显著正相关。本研究获得的Q-pac值随着年龄的增长而增加。缺乏统计上显著的偏差表明该方法是有用的。结论:MVD是一种可重复的方法,因为观察者之间没有显著的差异,并且对于经验不足的放射科医生在早期工作生涯中可以很容易地检测出青春期前扭转等急性阴囊病变。因此,在评估儿童急诊病例时,对伴随放射住院医师的高级指导的需求可能会减少。关键词:血供,微V多普勒,儿童年龄人群
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
28
审稿时长
3 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信