Comparing Signal to Noise Ratios of Amplitude Modulation Following Responses from four EEG Derivations in Awake Normally Hearing Adults: Comparando tasas señal/ruido para modulación de amplitud en seguimiento a respuestas de cuatro derivaciones del EEG en adultos normo-oyentes despiertos
Christoph S. van der Reijden, Lucas H. M. Mens, A. Snik
{"title":"Comparing Signal to Noise Ratios of Amplitude Modulation Following Responses from four EEG Derivations in Awake Normally Hearing Adults: Comparando tasas señal/ruido para modulación de amplitud en seguimiento a respuestas de cuatro derivaciones del EEG en adultos normo-oyentes despiertos","authors":"Christoph S. van der Reijden, Lucas H. M. Mens, A. Snik","doi":"10.3109/00206090109073115","DOIUrl":null,"url":null,"abstract":"Amplitude modulation following responses (AMFR) or steady-state evoked potentials (SSEPs) can be used for the objective and frequency-specific estimation of hearing thresholds in awake and sleeping subjects. To be useful as a clinical tool, a high signal to noise ratio (SNR) is required for a minimal testing time. Four EEG derivations were compared in six relaxed, cooperative awake normally hearing adults to compare the SNRs. Stimuli comprised a 1 kHz carrier wave, amplitude modulated at 39 Hz and 90 Hz. They were presented for about 4.4 min in one ear at a level slightly above the behavioural threshold (10 dB SL). In the 39 Hz condition, the SNRs from the different derivations did not differ significantly. However, in the 90 Hz condition one novel derivation (Cz-inion with ground at Pz) yielded a significantly lower noise level, about 60 per cent of the noise level of the other derivations. The SNR of this derivation was about 50 per cent larger than from other derivations. Such an increase of the SNR implies that testing time is reduced by about 56 per cent as compared to conventional derivations in these subjects. Las respuestas de seguimiento a la modulación de la amplitud (amplitud modulation following responses - AMFR) o los potenciales evocados de estado estable (steady-state evoked potentials -SSEP) pueden ser utilizados para la estimación de umbrales auditivos objetivos y de frecuecia-especifica, en sujetos dormidos y despiertos. Para ser útiles como herramienta clinica, se requiere una tasa señal/ruido alta (signal-to-noise ratio -SNR) por un tiempo minimo de evaluación. Se compararon cuatro derivaciones del EEG en seis adultos normo-oyentes, despiertos, cooperadores y relajados, para cvaluar las tasas de señal/ruido. Los estimulos involucraron una onda portadora dc 1 kHz, con amplitud modulada a 39 Hz y a 90 Hz. Los sujetos fueron estimulados por unos 4.4 minutos en cada oído, a un nivel apenas por encima de su umbral conductual (10 dB SL). En la condició de 39 Hz, los SNR de las difcrentes derivaciones no variaron significativamente. Sin embargo, en la condición de 90 Hz, una derivación novedosa (Cz-Inion con tierra en Pz) rindió un nivel de ruido significativamente más bajo, cerca del 60% del nivel de ruido de las otras derivaciones. EL SNR de esta derivación fue alrededor de un 50 por ciento más grande que el de otras derivaciones. Tal incremento del SNR implica que el tiempo de evaluación se reduce en un 56 por ciento, en comparación con las derivaciones convencionales en estos sujetos.","PeriodicalId":30299,"journal":{"name":"Audiology","volume":"40 1","pages":"202 - 207"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00206090109073115","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/00206090109073115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
Amplitude modulation following responses (AMFR) or steady-state evoked potentials (SSEPs) can be used for the objective and frequency-specific estimation of hearing thresholds in awake and sleeping subjects. To be useful as a clinical tool, a high signal to noise ratio (SNR) is required for a minimal testing time. Four EEG derivations were compared in six relaxed, cooperative awake normally hearing adults to compare the SNRs. Stimuli comprised a 1 kHz carrier wave, amplitude modulated at 39 Hz and 90 Hz. They were presented for about 4.4 min in one ear at a level slightly above the behavioural threshold (10 dB SL). In the 39 Hz condition, the SNRs from the different derivations did not differ significantly. However, in the 90 Hz condition one novel derivation (Cz-inion with ground at Pz) yielded a significantly lower noise level, about 60 per cent of the noise level of the other derivations. The SNR of this derivation was about 50 per cent larger than from other derivations. Such an increase of the SNR implies that testing time is reduced by about 56 per cent as compared to conventional derivations in these subjects. Las respuestas de seguimiento a la modulación de la amplitud (amplitud modulation following responses - AMFR) o los potenciales evocados de estado estable (steady-state evoked potentials -SSEP) pueden ser utilizados para la estimación de umbrales auditivos objetivos y de frecuecia-especifica, en sujetos dormidos y despiertos. Para ser útiles como herramienta clinica, se requiere una tasa señal/ruido alta (signal-to-noise ratio -SNR) por un tiempo minimo de evaluación. Se compararon cuatro derivaciones del EEG en seis adultos normo-oyentes, despiertos, cooperadores y relajados, para cvaluar las tasas de señal/ruido. Los estimulos involucraron una onda portadora dc 1 kHz, con amplitud modulada a 39 Hz y a 90 Hz. Los sujetos fueron estimulados por unos 4.4 minutos en cada oído, a un nivel apenas por encima de su umbral conductual (10 dB SL). En la condició de 39 Hz, los SNR de las difcrentes derivaciones no variaron significativamente. Sin embargo, en la condición de 90 Hz, una derivación novedosa (Cz-Inion con tierra en Pz) rindió un nivel de ruido significativamente más bajo, cerca del 60% del nivel de ruido de las otras derivaciones. EL SNR de esta derivación fue alrededor de un 50 por ciento más grande que el de otras derivaciones. Tal incremento del SNR implica que el tiempo de evaluación se reduce en un 56 por ciento, en comparación con las derivaciones convencionales en estos sujetos.
振幅调制反应后电位(AMFR)或稳态诱发电位(ssep)可用于客观和频率特异性估计清醒和睡眠受试者的听力阈值。作为一个有用的临床工具,高信噪比(SNR)需要在最短的测试时间。比较6例放松、合作、清醒的正常听力成人的4种脑电图衍生,比较信噪比。刺激包括1千赫载波,振幅在39赫兹和90赫兹调制。它们在一只耳朵中以略高于行为阈值(10 dB SL)的水平呈现约4.4分钟。在39 Hz的条件下,不同衍生的信噪比没有显著差异。然而,在90赫兹的条件下,一种新的衍生(Cz-inion与地面在Pz)产生的噪音水平明显较低,约为其他衍生噪音水平的60%。这种推导的信噪比比其他推导的信噪比大50%左右。这样的信噪比的增加意味着测试时间减少了约56%,与传统的衍生在这些科目。Las respuestas de seguimiento a la modulación de la amplitude (amplitude modulation following responses - AMFR), los potentiales evocados de estado estable (steady-state evoked potentials - ssep) puedser utilizados para la estimación de umbrales auditivos obtivos通过free - specific, en sujetos dormidos通过despiertos。Para ser útiles在临床诊断中,需要用到的参数为señal/信噪比(snr),即时间最小值为evaluación。本文比较了成人、正常人、青少年、青少年、青少年和青少年的脑电图特征。在1 kHz、39 Hz和90 Hz的调幅范围内,测量了两种不同的振幅。实验对象的脑电刺激持续时间为4.4分钟,时间长度为oído (10 dB SL)。当频率为condició 39 Hz时,信号的信噪比不同,但无显著性差异。Sin禁运,en la condición de 90 Hz, una derivación novedosa (Cz-Inion contierra en Pz) rindió unnivel de ruido significativamente más bajo, cerca del 60% de nivel de ruido de las tras衍生产品。EL SNR de esta derivación fue alreddeor de un50穷的ciento más grande que EL de otras derivaciones。Tal incremento德尔信噪比implica,《时代报》联合国56腰围超过evaluacion se减少ciento, en comparacion con las derivaciones convencionales en来说sujetos。