Dosimetria in vivo em tumores de mama: comparação entre a dose medida e calculada

Saude Tecnologia Pub Date : 2016-09-20 DOI:10.25758/SET.1371
A. Roma, Inês Ruas, R. Rocha, V. Gonçalves, A. Sá, Cátia Águas, Emmanuel Bonnarens, C. Coelho, Fátima Monsanto, E. Carolino
{"title":"Dosimetria in vivo em tumores de mama: comparação entre a dose medida e calculada","authors":"A. Roma, Inês Ruas, R. Rocha, V. Gonçalves, A. Sá, Cátia Águas, Emmanuel Bonnarens, C. Coelho, Fátima Monsanto, E. Carolino","doi":"10.25758/SET.1371","DOIUrl":null,"url":null,"abstract":"Introduction – In vivo dosimetry is useful in measuring the dose administered to patients during treatment, assessing significant differences between the prescribed dose and the dose to the target volume and the organs at risk. Purpose – To compare the measured dose with the calculated dose in patients with breast tumours with and without physical wedge. Methods – Entrance dose measurements using p-type diodes were performed for tangential fields and relative field-in-field in all 38 patients. Results – Statistically significant differences in open tangential fields ( ρ =0.000) were verified. Discussion – Studies report significant systematic deviations between planned and measured dose. Conclusion – With this study we conclude that there is no influence in the doses due to the presence of the physical wedge.","PeriodicalId":30555,"journal":{"name":"Saude Tecnologia","volume":"64 1","pages":"34-38"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saude Tecnologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25758/SET.1371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction – In vivo dosimetry is useful in measuring the dose administered to patients during treatment, assessing significant differences between the prescribed dose and the dose to the target volume and the organs at risk. Purpose – To compare the measured dose with the calculated dose in patients with breast tumours with and without physical wedge. Methods – Entrance dose measurements using p-type diodes were performed for tangential fields and relative field-in-field in all 38 patients. Results – Statistically significant differences in open tangential fields ( ρ =0.000) were verified. Discussion – Studies report significant systematic deviations between planned and measured dose. Conclusion – With this study we conclude that there is no influence in the doses due to the presence of the physical wedge.
乳腺肿瘤体内剂量测定:测量剂量与计算剂量的比较
体内剂量法可用于测量治疗期间给予患者的剂量,评估处方剂量与靶体积和危险器官的剂量之间的显着差异。目的:比较具有和不具有物理楔形的乳腺肿瘤患者的测量剂量与计算剂量。方法:采用p型二极管对38例患者进行切向场和相对场对场的入口剂量测量。结果-证实了开切场的统计学显著差异(ρ =0.000)。讨论-研究报告计划剂量和测量剂量之间存在显著的系统性偏差。结论-通过这项研究,我们得出结论,由于物理楔的存在,对剂量没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
16
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信