Presence of a Hernia Sac Does Not Impact Lung Perfusion in CDH

Ramaraj Akila B, Jensen Guy, Kinghorn Bre Anna, Stark Rebecca A
{"title":"Presence of a Hernia Sac Does Not Impact Lung Perfusion in CDH","authors":"Ramaraj Akila B, Jensen Guy, Kinghorn Bre Anna, Stark Rebecca A","doi":"10.23937/2378-3516/1410161","DOIUrl":null,"url":null,"abstract":"Purpose: There are variable long-term pulmonary outcomes of children with congenital diaphragmatic hernia (CDH). Diagnostic modalities evaluating pulmonary function can be limited by patient compliance. Pulmonary perfusion scintigraphy is a diagnostic tool to evaluate lung development in younger children. Presence of a hernia sac is known to correlate with less severe disease but little has been reported on any correlation with lung size and function. The purpose of this study was to evaluate the relationship between presence of a hernia sac, pulmonary perfusion and CDH defect size. Methods: Records of all children treated for CDH at our institution from January 2009 to December 2018 were reviewed. A subset of these children underwent lung perfusion scintigraphy. We hypothesized that the presence of a hernia sac would affect future perfusion studies. We assessed this with two linear regression models. Results: One hundred thirty-three children were treated for CDH over 10 years. Twenty-nine children (22%) underwent pulmonary scintigraphy, 9 of whom (31%) had a hernia sac. There was no correlation between hernia sac presence and improved perfusion (R2 = 0.005, p = 0.7). There was a correlation between area of the defect (cm2), and perfusion difference between the two lungs (R2 = 0.56, p < 0.05). When adjusting for presence of the hernia sac, the fit of the model was unchanged (R2 = 0.57, p < 0.05). Conclusions: As expected, there is a correlation between CDH defect size and lung perfusion. However, presence of a hernia sac did not impact lung function as determined by perfusion scintigraphy.","PeriodicalId":91516,"journal":{"name":"International journal of respiratory and pulmonary medicine","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of respiratory and pulmonary medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23937/2378-3516/1410161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: There are variable long-term pulmonary outcomes of children with congenital diaphragmatic hernia (CDH). Diagnostic modalities evaluating pulmonary function can be limited by patient compliance. Pulmonary perfusion scintigraphy is a diagnostic tool to evaluate lung development in younger children. Presence of a hernia sac is known to correlate with less severe disease but little has been reported on any correlation with lung size and function. The purpose of this study was to evaluate the relationship between presence of a hernia sac, pulmonary perfusion and CDH defect size. Methods: Records of all children treated for CDH at our institution from January 2009 to December 2018 were reviewed. A subset of these children underwent lung perfusion scintigraphy. We hypothesized that the presence of a hernia sac would affect future perfusion studies. We assessed this with two linear regression models. Results: One hundred thirty-three children were treated for CDH over 10 years. Twenty-nine children (22%) underwent pulmonary scintigraphy, 9 of whom (31%) had a hernia sac. There was no correlation between hernia sac presence and improved perfusion (R2 = 0.005, p = 0.7). There was a correlation between area of the defect (cm2), and perfusion difference between the two lungs (R2 = 0.56, p < 0.05). When adjusting for presence of the hernia sac, the fit of the model was unchanged (R2 = 0.57, p < 0.05). Conclusions: As expected, there is a correlation between CDH defect size and lung perfusion. However, presence of a hernia sac did not impact lung function as determined by perfusion scintigraphy.
疝囊的存在不影响CDH患者的肺灌注
目的:先天性膈疝(CDH)患儿的长期肺预后是可变的。评估肺功能的诊断方式可能受到患者依从性的限制。肺灌注显像是评估低龄儿童肺发育的诊断工具。已知疝囊的存在与较轻的疾病相关,但很少有与肺大小和功能相关的报道。本研究的目的是评估疝囊存在、肺灌注和CDH缺损大小之间的关系。方法:回顾我院2009年1月至2018年12月收治的所有CDH患儿的记录。这些儿童中的一部分接受了肺灌注显像。我们假设疝囊的存在会影响未来的灌注研究。我们用两个线性回归模型来评估这一点。结果:133名儿童在10年内接受了CDH治疗。29例患儿(22%)行肺显像检查,其中9例患儿(31%)有疝囊。疝囊存在与灌注改善无相关性(R2 = 0.005, p = 0.7)。缺损面积(cm2)与两肺灌注差有相关性(R2 = 0.56, p < 0.05)。在调整是否存在疝囊后,模型的拟合没有变化(R2 = 0.57, p < 0.05)。结论:正如预期的那样,CDH缺损大小与肺灌注有相关性。然而,经灌注显像检查,疝囊的存在并不影响肺功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书