Fluctuant tonus of the coronary arteries possibly documented by repeated multidetector row computed tomography

IF 0.5 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Ikuko Anan, K. Hongo, M. Kawai, Kazuo Ogawa, T. Sakuma, K. Fukuda, I. Taniguchi, M. Yoshimura
{"title":"Fluctuant tonus of the coronary arteries possibly documented by repeated multidetector row computed tomography","authors":"Ikuko Anan, K. Hongo, M. Kawai, Kazuo Ogawa, T. Sakuma, K. Fukuda, I. Taniguchi, M. Yoshimura","doi":"10.2147/RRCC.S72464","DOIUrl":null,"url":null,"abstract":"Objective: Recent advances in multidetector row computed tomography (MDCT) have made it possible to diagnose coronary stenosis with high sensitivity. However, coronary arterial tonus has not been considered when reading MDCT. We hypothesized that MDCT can document fluctuant tonus of the coronary arteries. Methods: The study population consisted of 39 consecutive patients who underwent MDCT twice in our institution with 64-row dual-source MDCT. Measurements were performed with stretched multiplanar reconstruction images using the full width at half maximum method. The coronary arteries were measured at each segment, and the same measurement was performed in the ascending aorta and the left internal thoracic artery (ITA). The percent diameter changes between the first and second measurements were examined in each segment of the coronary arteries and compared with those in the aorta or the ITA. Results: The average percent diameter changes were statistically equivalent between the coronary arteries and the aorta or the ITA. On the other hand, the percent diameter changes in distribution were significantly larger in the coronary arteries than those in the aorta or the ITA. This suggests that the diameter of the coronary arteries is liable to show variation compared to that of other arteries. Conclusion: This study confirmed for the first time that coronary arteries can fluctuate sub-stantially and that these changes can be documented by MDCT. Changes in coronary arterial tonus should therefore be considered when reading MDCT. row computed tomography; CCB, calcium channel blocker; aCe-i, angiotensin-converting enzyme inhibitor; isDn, isosorbide dinitrate.","PeriodicalId":42306,"journal":{"name":"Research Reports in Clinical Cardiology","volume":"5 1","pages":"327-337"},"PeriodicalIF":0.5000,"publicationDate":"2014-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/RRCC.S72464","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research Reports in Clinical Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/RRCC.S72464","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Recent advances in multidetector row computed tomography (MDCT) have made it possible to diagnose coronary stenosis with high sensitivity. However, coronary arterial tonus has not been considered when reading MDCT. We hypothesized that MDCT can document fluctuant tonus of the coronary arteries. Methods: The study population consisted of 39 consecutive patients who underwent MDCT twice in our institution with 64-row dual-source MDCT. Measurements were performed with stretched multiplanar reconstruction images using the full width at half maximum method. The coronary arteries were measured at each segment, and the same measurement was performed in the ascending aorta and the left internal thoracic artery (ITA). The percent diameter changes between the first and second measurements were examined in each segment of the coronary arteries and compared with those in the aorta or the ITA. Results: The average percent diameter changes were statistically equivalent between the coronary arteries and the aorta or the ITA. On the other hand, the percent diameter changes in distribution were significantly larger in the coronary arteries than those in the aorta or the ITA. This suggests that the diameter of the coronary arteries is liable to show variation compared to that of other arteries. Conclusion: This study confirmed for the first time that coronary arteries can fluctuate sub-stantially and that these changes can be documented by MDCT. Changes in coronary arterial tonus should therefore be considered when reading MDCT. row computed tomography; CCB, calcium channel blocker; aCe-i, angiotensin-converting enzyme inhibitor; isDn, isosorbide dinitrate.
冠状动脉张力波动可能由多次多排计算机断层扫描记录
目的:近年来多排计算机断层扫描(MDCT)技术的发展使冠状动脉狭窄的高灵敏度诊断成为可能。然而,在MDCT阅读时,冠状动脉张力未被考虑。我们假设多层螺旋ct可以记录冠状动脉张力波动。方法:研究人群包括39例在我院连续接受两次64排双源MDCT的患者。测量是用拉伸的多平面重建图像进行的,使用全宽度半最大值方法。在各节段测量冠状动脉,并在升主动脉和左胸内动脉(ITA)进行相同的测量。第一次和第二次测量之间的直径变化百分比在冠状动脉的每一段进行检查,并与主动脉或ITA的测量结果进行比较。结果:冠状动脉与主动脉或ITA之间的平均直径变化百分比具有统计学意义。另一方面,冠状动脉的直径变化百分比明显大于主动脉或ITA。这表明与其他动脉相比,冠状动脉的直径容易发生变化。结论:本研究首次证实冠状动脉可以有明显的波动,这些变化可以通过MDCT记录。因此,在进行多层螺旋ct检查时应考虑冠状动脉张力的变化。行计算机断层扫描;钙通道阻滞剂;aCe-i,血管紧张素转换酶抑制剂;isDn,硝酸异山梨酯。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Research Reports in Clinical Cardiology
Research Reports in Clinical Cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
自引率
0.00%
发文量
11
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信