{"title":"Performance Analysis of a Linear Oscillatory Actuator for a Milking Unit","authors":"N. Nishizawa;T. Ishii;H. Yamada","doi":"10.1109/TJMJ.1994.4565968","DOIUrl":null,"url":null,"abstract":"Milking with a conventional milking machine often involves teat trouble, because the pulsation rate of the milking is not variable. A new cylindrical linear oscillatory actuator (CLOA) developed by the authors has a freely variable pulsation rate. This paper analyzes the static and kinetic thrusts of the CLOA. The mover of the CLOA is capable of oscillation at a frequency of 1 Hz with a stroke of ±2 mm, and will be used in new milking machines.","PeriodicalId":100647,"journal":{"name":"IEEE Translation Journal on Magnetics in Japan","volume":"9 6","pages":"122-126"},"PeriodicalIF":0.0000,"publicationDate":"1994-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TJMJ.1994.4565968","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Translation Journal on Magnetics in Japan","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/4565968/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Milking with a conventional milking machine often involves teat trouble, because the pulsation rate of the milking is not variable. A new cylindrical linear oscillatory actuator (CLOA) developed by the authors has a freely variable pulsation rate. This paper analyzes the static and kinetic thrusts of the CLOA. The mover of the CLOA is capable of oscillation at a frequency of 1 Hz with a stroke of ±2 mm, and will be used in new milking machines.
挤奶机组线性振荡执行器的性能分析
使用传统挤奶机挤奶通常会遇到乳头故障,因为挤奶的脉动率是不可变的。作者开发的一种新型圆柱形线性振荡执行器具有可自由变化的脉动率。本文分析了CLOA的静态推力和动态推力。CLOA的推进器能够以1 Hz的频率振荡,行程为±2 mm,并将用于新型挤奶机。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信