{"title":"Nanometrology Room Design: The Performance and Characterization of the Kevin G. Hall High-Accuracy Laboratory","authors":"J. Weaver, M. Voorhis, R. Reifenberger","doi":"10.17764/JIET.52.2.G43282648562475Q","DOIUrl":null,"url":null,"abstract":"New buildings focused on the practice of nanotechnology reflect a pressing need to develop advanced techniques to enable reliable work at the nanoscale. Often when planning a nanotechnology building, a decision must be made to include high-accuracy nanometrology rooms. The purpose of these rooms is to provide high-quality space that can be utilized on a daily basis to facilitate experiments requiring nanoscale precision, to develop new instrumentation, and to develop new techniques capable of probing the nanoscale. Typically, these rooms reduce vibration (including acoustic noise) and electromagnetic interference to very low levels while maintaining a high level of temperature stability. This study describes the characterization and performance of the Kevin G. Hall Nanometrology Laboratory located in the Birck Nanotechnology Center at Purdue University.","PeriodicalId":35935,"journal":{"name":"Journal of the IEST","volume":"39 1","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the IEST","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17764/JIET.52.2.G43282648562475Q","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 4
Abstract
New buildings focused on the practice of nanotechnology reflect a pressing need to develop advanced techniques to enable reliable work at the nanoscale. Often when planning a nanotechnology building, a decision must be made to include high-accuracy nanometrology rooms. The purpose of these rooms is to provide high-quality space that can be utilized on a daily basis to facilitate experiments requiring nanoscale precision, to develop new instrumentation, and to develop new techniques capable of probing the nanoscale. Typically, these rooms reduce vibration (including acoustic noise) and electromagnetic interference to very low levels while maintaining a high level of temperature stability. This study describes the characterization and performance of the Kevin G. Hall Nanometrology Laboratory located in the Birck Nanotechnology Center at Purdue University.
以纳米技术实践为重点的新建筑反映了发展先进技术以实现纳米尺度上可靠工作的迫切需要。通常在规划纳米技术建筑时,必须决定包括高精度的纳米计量室。这些房间的目的是提供高质量的空间,可以在日常基础上利用,以促进需要纳米级精度的实验,开发新的仪器,并开发能够探测纳米级的新技术。通常,这些房间将振动(包括噪音)和电磁干扰降低到非常低的水平,同时保持高度的温度稳定性。本研究描述了位于普渡大学Birck纳米技术中心的Kevin G. Hall纳米计量实验室的表征和性能。
期刊介绍:
The Journal of the IEST is an official publication of the Institute of Environmental Sciences and Technology and is of archival quality and noncommercial in nature. It was established to advance knowledge through technical articles selected by peer review, and has been published for over 50 years as a benefit to IEST members and the technical community at large as as a permanent record of progress in the science and technology of the environmental sciences