Massive Pseudotumor in a 28mm Ceramic-Polyethylene Revision THA: A Case Report

Facs Edward McPherson, Ba Matthew Dipane, S. Sherif
{"title":"Massive Pseudotumor in a 28mm Ceramic-Polyethylene Revision THA: A Case Report","authors":"Facs Edward McPherson, Ba Matthew Dipane, S. Sherif","doi":"10.15438/RR.V4I1.53","DOIUrl":null,"url":null,"abstract":"This report reviews the findings of a massive pseudotumor detected pre-operatively in a 13-year-old revision total hip arthroplasty. The case is unique in that the bearing involved was a 28mm zirconia ceramic head on a polyethylene liner. We propose that the pseudotumor arose from ultrafine titanium par ticles liberated from the proximal porous coating of the femoral stem. We suspect that the osteolysis produced from polyethylene wear exposed the proximal porous coating and, via a process of mechanical abrasion with the surrounding soft tissues, liberated ultrafine titanium particles. We believe the pseudotumor formed because the patient was pre-sensitized to metal debris based upon a pre-operative lymphocyte T-cell proliferation test (LTT). Based upon this unique case, we feel that pseudotumors more likely form when there is a high rate of ultrafine metal particles generated in a pre-sensitized patient. Finally, we introduce what we believe are the main biologic wear responses in THA. Further research is needed to validate this proposed model.","PeriodicalId":20884,"journal":{"name":"Reconstructive Review","volume":"4 1","pages":"11-17"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reconstructive Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15438/RR.V4I1.53","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

This report reviews the findings of a massive pseudotumor detected pre-operatively in a 13-year-old revision total hip arthroplasty. The case is unique in that the bearing involved was a 28mm zirconia ceramic head on a polyethylene liner. We propose that the pseudotumor arose from ultrafine titanium par ticles liberated from the proximal porous coating of the femoral stem. We suspect that the osteolysis produced from polyethylene wear exposed the proximal porous coating and, via a process of mechanical abrasion with the surrounding soft tissues, liberated ultrafine titanium particles. We believe the pseudotumor formed because the patient was pre-sensitized to metal debris based upon a pre-operative lymphocyte T-cell proliferation test (LTT). Based upon this unique case, we feel that pseudotumors more likely form when there is a high rate of ultrafine metal particles generated in a pre-sensitized patient. Finally, we introduce what we believe are the main biologic wear responses in THA. Further research is needed to validate this proposed model.
28mm陶瓷-聚乙烯全髋关节置换术中巨大假瘤1例
本报告回顾了在13岁的全髋关节置换术中术前发现的巨大假肿瘤的发现。该案例的独特之处在于,所涉及的轴承是一个28毫米的氧化锆陶瓷头在聚乙烯衬垫上。我们认为假肿瘤是由股骨干近端多孔涂层释放的超细钛颗粒引起的。我们怀疑聚乙烯磨损产生的骨溶解暴露了近端多孔涂层,并通过与周围软组织的机械磨损过程释放出超细钛颗粒。根据术前淋巴细胞t细胞增殖试验(LTT),我们认为假性肿瘤的形成是因为患者对金属碎片预先敏感。基于这个独特的病例,我们认为在预致敏的患者中,当超细金属颗粒的产生率很高时,假肿瘤更有可能形成。最后,我们介绍了我们认为THA中主要的生物磨损反应。需要进一步的研究来验证所提出的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
2
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信