Avaliação da distorção da curvatura em canais simulados, instrumentados por dois sistemas rotatórios: Quantec Series 2000TM e RBSTM Moyco Union Broach

C. Costa, Marcelo Bidóia dos Santos, Antônio Carlos Bombana
{"title":"Avaliação da distorção da curvatura em canais simulados, instrumentados por dois sistemas rotatórios: Quantec Series 2000TM e RBSTM Moyco Union Broach","authors":"C. Costa, Marcelo Bidóia dos Santos, Antônio Carlos Bombana","doi":"10.1590/S0103-06631999000400012","DOIUrl":null,"url":null,"abstract":"The authors evaluated, in simulated curved canals, the distortion caused by the use of two rotary systems, the Quantec and the RBS. Twenty epoxy resin simulated root canals were obtained through silver cones #15 with 21 mm and 30 degree curves, checked by a profile projector, according to Schneider \"modified\" technique, and divided in two groups. They were covered with black adhesive band and instrumented, with the respective rotary systems, according to the manufacturer’s directions, up to size 35 at the apex. After instrumentation, the blocks were uncovered and the angle of each prepared canal was measured again, thus revealing the curvature distortion of the canals through a percental distortion index. The results showed that for the Quantec system the percental average distortion was 8.14%, while that for the RBS was 12.48%, difference statistically significant at the level of 1% (a = 0.01%).","PeriodicalId":77611,"journal":{"name":"Revista de odontologia da Universidade de Sao Paulo","volume":"13 1","pages":"391-394"},"PeriodicalIF":0.0000,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de odontologia da Universidade de Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0103-06631999000400012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The authors evaluated, in simulated curved canals, the distortion caused by the use of two rotary systems, the Quantec and the RBS. Twenty epoxy resin simulated root canals were obtained through silver cones #15 with 21 mm and 30 degree curves, checked by a profile projector, according to Schneider "modified" technique, and divided in two groups. They were covered with black adhesive band and instrumented, with the respective rotary systems, according to the manufacturer’s directions, up to size 35 at the apex. After instrumentation, the blocks were uncovered and the angle of each prepared canal was measured again, thus revealing the curvature distortion of the canals through a percental distortion index. The results showed that for the Quantec system the percental average distortion was 8.14%, while that for the RBS was 12.48%, difference statistically significant at the level of 1% (a = 0.01%).
采用Quantec系列2000TM和RBSTM Moyco Union Broach两种旋转系统对模拟通道的曲率失真进行评估
在模拟的弯曲运河中,作者评估了两种旋转系统(Quantec和RBS)的使用所造成的扭曲。根据施耐德“改良”技术,通过15号银锥获得20个环氧树脂模拟根管,具有21毫米和30度曲线,由轮廓投影仪检查,并分为两组。它们被黑色胶带覆盖,并根据制造商的说明,用各自的旋转系统进行测量,在顶端达到35号。器械完成后,揭去砌块,再次测量各预备管的角度,通过百分比扭曲指数揭示管的曲率扭曲。结果表明,Quantec系统的平均失真百分比为8.14%,RBS系统的平均失真百分比为12.48%,在1%水平下差异有统计学意义(a = 0.01%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信