{"title":"Análise da irradiação de diversos aparelhos fotopolimerizadores","authors":"G. Vieira, Ismael Antônio Freire, Carlos Martins Agra, Jane Cleide Goveia, Edmir Matson","doi":"10.1590/S0103-06631998000400015","DOIUrl":null,"url":null,"abstract":"The authors have studied five different visible light-curing devices to verify the irradiance they are able to emit. Using optical instruments like a spectrophotometer and a monochromator, the authors have analyzed the transmittance of the filters, the characteristics of the light radiation source (lamp) and the performance of the ends. They have concluded that the visible light-curing devices analyzed emitted energy in a proper wavelenght, that is, between 350 and 530 nm, with the highest concentration in the range of 430 to 470 nm.","PeriodicalId":77611,"journal":{"name":"Revista de odontologia da Universidade de Sao Paulo","volume":"12 1","pages":"395-399"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de odontologia da Universidade de Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0103-06631998000400015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

The authors have studied five different visible light-curing devices to verify the irradiance they are able to emit. Using optical instruments like a spectrophotometer and a monochromator, the authors have analyzed the transmittance of the filters, the characteristics of the light radiation source (lamp) and the performance of the ends. They have concluded that the visible light-curing devices analyzed emitted energy in a proper wavelenght, that is, between 350 and 530 nm, with the highest concentration in the range of 430 to 470 nm.
各种光固化装置的辐照分析
作者研究了五种不同的可见光固化装置,以验证它们能够发出的辐照度。利用分光光度计和单色仪等光学仪器,分析了滤光片的透光率、光源(灯)的特性和端部的性能。他们得出的结论是,所分析的可见光固化装置发射的能量在适当的波长,即350至530纳米之间,在430至470纳米范围内浓度最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书