Droplet spectrum characteristics and drift potential of different droplet classes and spray volumes application of atrazine with nicosulfuron

IF 0.8 4区 农林科学 Q3 AGRONOMY
Arthur Duarte Rodrigues Neto, Naiane Antunes Alves Ribeiro, Fagner Angelo da Silva e Oliveira, G. A. Faria, E. P. Prado
{"title":"Droplet spectrum characteristics and drift potential of different droplet classes and spray volumes application of atrazine with nicosulfuron","authors":"Arthur Duarte Rodrigues Neto, Naiane Antunes Alves Ribeiro, Fagner Angelo da Silva e Oliveira, G. A. Faria, E. P. Prado","doi":"10.1590/0103-8478cr20220509","DOIUrl":null,"url":null,"abstract":"ABSTRACT: In this research, the Volumetric Median Diameters (VMDs), Relative Span (RS), percentage of droplets with a diameter smaller than 100 µm (V100), and percentage ofdrift (% drift) of four droplet classes (Fine, Medium, Coarse, and Very Coarse) were analyzedin two spray volumes (77 L.ha-1and 144 L.ha-1) employinga tank-mix of atrazine and nicosulfuron herbicides (2500 + 15 gaiha-1), usingParticle/Droplet Imaging Analyze (PDIA) and wind tunnel techniques. The experiments were performed under Completely Randomized Design, in a 4 × 2 factorial scheme (droplet classes × sprayvolumes). Data underwent analysis of variance and Tukey’s test at 5%, and the correlation between variables was computedconsidering Pearson’s coefficient at 1% and 5%. The VMD of all droplet classes was considerably distinct in the two spray volumes. In both application spray volumes, the minimum VMD for the Coarsedropletclass classification was not attained. The highest means of RS were detectedin the spray volume of 77 L.ha-1. All treatments demonstratedsignificant differences in the analysis of V100 and % drift, with the highest means observed in the Fine droplet (144 L.ha-1) and Medium (77 L.ha-1). A negative correlation existed between VMD × V100 and VMD × % drift and a positive correlation between V100 × % drift in the two spray volumes. RS was negatively correlated with VMD and positively with V100 and % drift, in the spray volume of 77 L.ha-1. In the spray volume of 144 L.ha-1, the correlation between RSand VMD, V100, and % drift was insignificant.","PeriodicalId":10308,"journal":{"name":"Ciencia Rural","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ciencia Rural","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1590/0103-8478cr20220509","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AGRONOMY","Score":null,"Total":0}
引用次数: 1

Abstract

ABSTRACT: In this research, the Volumetric Median Diameters (VMDs), Relative Span (RS), percentage of droplets with a diameter smaller than 100 µm (V100), and percentage ofdrift (% drift) of four droplet classes (Fine, Medium, Coarse, and Very Coarse) were analyzedin two spray volumes (77 L.ha-1and 144 L.ha-1) employinga tank-mix of atrazine and nicosulfuron herbicides (2500 + 15 gaiha-1), usingParticle/Droplet Imaging Analyze (PDIA) and wind tunnel techniques. The experiments were performed under Completely Randomized Design, in a 4 × 2 factorial scheme (droplet classes × sprayvolumes). Data underwent analysis of variance and Tukey’s test at 5%, and the correlation between variables was computedconsidering Pearson’s coefficient at 1% and 5%. The VMD of all droplet classes was considerably distinct in the two spray volumes. In both application spray volumes, the minimum VMD for the Coarsedropletclass classification was not attained. The highest means of RS were detectedin the spray volume of 77 L.ha-1. All treatments demonstratedsignificant differences in the analysis of V100 and % drift, with the highest means observed in the Fine droplet (144 L.ha-1) and Medium (77 L.ha-1). A negative correlation existed between VMD × V100 and VMD × % drift and a positive correlation between V100 × % drift in the two spray volumes. RS was negatively correlated with VMD and positively with V100 and % drift, in the spray volume of 77 L.ha-1. In the spray volume of 144 L.ha-1, the correlation between RSand VMD, V100, and % drift was insignificant.
氟磺隆与阿特拉津在不同雾滴类别和喷雾量下的光谱特性及漂移势
摘要:本研究采用颗粒/液滴成像分析(PDIA)和风洞技术,以阿特拉津和nico硫隆除草剂(2500 + 15 gaiha-1)为混合剂,在77 L.ha-1和144 L.ha-1两种喷雾体积(77 L.ha-1)中,分析了细、中、粗、极粗四种液滴的体积中值直径(VMDs)、相对跨度(RS)、直径小于100 μ m的液滴百分比(V100)和漂移百分比(%漂移)。试验采用完全随机设计,采用4 × 2因子方案(液滴类别×喷雾量)。数据进行方差分析和5%的Tukey检验,并考虑1%和5%的Pearson系数计算变量之间的相关性。在两种喷雾体积中,所有液滴类别的VMD差异很大。在两种应用喷雾体积下,未达到粗滴分类的最小VMD。喷淋量为77 L.ha-1时,RS均值最高。所有处理在V100和%漂移分析上均表现出显著差异,其中细滴(144 L.ha-1)和中滴(77 L.ha-1)的平均值最高。两种喷雾体积的VMD × V100与VMD × %漂移呈负相关,V100 × %漂移呈正相关。在77 L.ha-1喷雾量下,RS与VMD呈负相关,与V100和%漂移呈正相关。在144 L.ha-1的喷雾量下,rr与VMD、V100、%漂移的相关性不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ciencia Rural
Ciencia Rural AGRONOMY-
CiteScore
1.70
自引率
0.00%
发文量
233
审稿时长
2-4 weeks
期刊介绍: The purpose of Ciência Rural is to publish the results of original research, note and reviews which contribute significantly to knowledge in Agricultural Sciences. Preference will be given to original articles that develop news concepts or experimental approaches and are not merely repositories of scientific data. The decison of acceptance for publication lies with the Editors and is based on the recommendations of Editorial Comission, Area Committee and/ or ad hoc reviewers. The editors and reviewers are external to the institution.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信