Numerical Analysis of the Seismic Performance of Rigid Beam-To-Column Moment Connections Equipped with Steel Slit Damper (SSD)

IF 1.4 4区 工程技术 Q3 ENGINEERING, CIVIL
M. Hosseini, Liao Haitao, I. Corbi, O. Corbi
{"title":"Numerical Analysis of the Seismic Performance of Rigid Beam-To-Column Moment Connections Equipped with Steel Slit Damper (SSD)","authors":"M. Hosseini, Liao Haitao, I. Corbi, O. Corbi","doi":"10.1590/1679-78256994","DOIUrl":null,"url":null,"abstract":": In the present research, the finite-element method (FEM) implemented in the ABAQUS software is used to evaluate several numerical models. This study presents a composite system of slit dampers coupled with column-attached seats, where excessive loading of the structural system leads to the yielding of the slit damper rather than damaging main structural elements, especially the beams. In this respect, four aspects of the behavior of such connections are herein investigated to come up with an in-depth insight; these include aspect ratio, distance ratio, compactness ratio","PeriodicalId":18192,"journal":{"name":"Latin American Journal of Solids and Structures","volume":"1 1","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Latin American Journal of Solids and Structures","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1590/1679-78256994","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 1

Abstract

: In the present research, the finite-element method (FEM) implemented in the ABAQUS software is used to evaluate several numerical models. This study presents a composite system of slit dampers coupled with column-attached seats, where excessive loading of the structural system leads to the yielding of the slit damper rather than damaging main structural elements, especially the beams. In this respect, four aspects of the behavior of such connections are herein investigated to come up with an in-depth insight; these include aspect ratio, distance ratio, compactness ratio
安装钢缝阻尼器(SSD)的梁柱刚性弯矩连接抗震性能数值分析
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
8.30%
发文量
37
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信