Seismic Design Of Precast Concrete Rocking Wall Systems With Varying Hysteretic Damping

IF 0.9 4区 工程技术 Q4 CONSTRUCTION & BUILDING TECHNOLOGY
PCI Journal Pub Date : 2019-01-01 DOI:10.15554/PCIJ64.5-04
M. Nazari, S. Sritharan
{"title":"Seismic Design Of Precast Concrete Rocking Wall Systems With Varying Hysteretic Damping","authors":"M. Nazari, S. Sritharan","doi":"10.15554/PCIJ64.5-04","DOIUrl":null,"url":null,"abstract":"Following the design practice for cast-in-place concrete walls in which energy dissipation is a byproduct of the walls’ seismic response, force-based seismic design of precast concrete rocking walls uses a response modi cation coef cient, or R factor, of 5 and a minimum equivalent viscous damping ratio of about 8%. However, single rocking walls (SRWs) with total damping of 6% and precast concrete walls with end columns (PreWECs) designed with as much as 16% damping showed satisfactory responses when subjected to shake-table testing. These ndings suggest that the current design approach used for precast concrete rocking walls is unnecessarily restrictive and does not account for the superior behavior of the wall systems in design. To overcome this challenge, a damping-dependent R is proposed for the seismic design of precast concrete rocking walls and its effectiveness is demonstrated using a parametric study. A cost index is also developed to determine the relative bene ts of SRWs and PreWECs.","PeriodicalId":54637,"journal":{"name":"PCI Journal","volume":"1 1","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PCI Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.15554/PCIJ64.5-04","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 7

Abstract

Following the design practice for cast-in-place concrete walls in which energy dissipation is a byproduct of the walls’ seismic response, force-based seismic design of precast concrete rocking walls uses a response modi cation coef cient, or R factor, of 5 and a minimum equivalent viscous damping ratio of about 8%. However, single rocking walls (SRWs) with total damping of 6% and precast concrete walls with end columns (PreWECs) designed with as much as 16% damping showed satisfactory responses when subjected to shake-table testing. These ndings suggest that the current design approach used for precast concrete rocking walls is unnecessarily restrictive and does not account for the superior behavior of the wall systems in design. To overcome this challenge, a damping-dependent R is proposed for the seismic design of precast concrete rocking walls and its effectiveness is demonstrated using a parametric study. A cost index is also developed to determine the relative bene ts of SRWs and PreWECs.
变滞回阻尼预制混凝土摇墙抗震设计
根据现浇混凝土墙体的设计实践,其中能量耗散是墙体地震反应的副产品,预制混凝土摇墙的基于力的抗震设计使用响应修正系数或R因子为5,最小等效粘性阻尼比约为8%。然而,在振动台试验中,总阻尼为6%的单摇墙(srw)和设计阻尼高达16%的端柱预制混凝土墙(PreWECs)表现出令人满意的响应。这些结论表明,目前用于预制混凝土摇墙的设计方法是不必要的限制,并且没有考虑到墙体系统在设计中的优越性能。为了克服这一挑战,提出了一种与阻尼相关的R用于预制混凝土摇墙的抗震设计,并通过参数化研究证明了其有效性。此外,还制定了成本指数,以确定srw和prewcs的相对效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
PCI Journal
PCI Journal 工程技术-结构与建筑技术
自引率
9.10%
发文量
15
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信