Visual Binary Testing Of Hydrogen Sulfide Dissolved In Return Underground Local-Water Of Oil And Gas Condensate Fields

IF 0.7 Q4 CHEMISTRY, ANALYTICAL
E. A. Reshetnyak, N. Nemets, O. Chernyshova, A. Panteleimonov, V. M. Ostrovskaya
{"title":"Visual Binary Testing Of Hydrogen Sulfide Dissolved In Return Underground Local-Water Of Oil And Gas Condensate Fields","authors":"E. A. Reshetnyak, N. Nemets, O. Chernyshova, A. Panteleimonov, V. M. Ostrovskaya","doi":"10.17721/moca.2019.146-152","DOIUrl":null,"url":null,"abstract":"In order to screen samples of return underground local-water of oil and gas condensate fields for the presence of dissolved hydrogen sulfide, it was proposed to use single comparison sample for visual binary testing of H2S. Two indicator reactions occurring in solutions were selected — the formation of a stabilized suspension of MnS and CdS. Suspensions prepared in the presence of borate buffer (pH 9.18) and gelatin (stabilizer) are stable during the twenty four hours; a difference in the turbidity of suspensions can be observed near the normalized concentration of hydrogen sulfide (сlim = 15 mg L-1). When establishing the concentration of H2S in the comparison samples, a statistical approach was applied; the estimated values of the threshold concentration of H2S (ccomp.) are less than the normalized level on the value which providing the risk of a false-negative test result not more than 5% - 11.6 mg L-1 for MnS and 13.4 mg L-1 for CdS. Preference was given to a test system based on a stabilized suspension of CdS, because for this reaction, a narrower interval of unreliability and the value of ccomp. is nearer to the value of the сlim. The correctness of the visual binary testing of H2S in the samples of the analyzed water was confirmed by spectrophotometric method with p-phenylenediamine.","PeriodicalId":18626,"journal":{"name":"Methods and Objects of Chemical Analysis","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Objects of Chemical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17721/moca.2019.146-152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

Abstract

In order to screen samples of return underground local-water of oil and gas condensate fields for the presence of dissolved hydrogen sulfide, it was proposed to use single comparison sample for visual binary testing of H2S. Two indicator reactions occurring in solutions were selected — the formation of a stabilized suspension of MnS and CdS. Suspensions prepared in the presence of borate buffer (pH 9.18) and gelatin (stabilizer) are stable during the twenty four hours; a difference in the turbidity of suspensions can be observed near the normalized concentration of hydrogen sulfide (сlim = 15 mg L-1). When establishing the concentration of H2S in the comparison samples, a statistical approach was applied; the estimated values of the threshold concentration of H2S (ccomp.) are less than the normalized level on the value which providing the risk of a false-negative test result not more than 5% - 11.6 mg L-1 for MnS and 13.4 mg L-1 for CdS. Preference was given to a test system based on a stabilized suspension of CdS, because for this reaction, a narrower interval of unreliability and the value of ccomp. is nearer to the value of the сlim. The correctness of the visual binary testing of H2S in the samples of the analyzed water was confirmed by spectrophotometric method with p-phenylenediamine.
油气凝析田回地下局部水中硫化氢溶解的视觉二元检测
为了筛选油气凝析田地下回水样品中是否存在溶解硫化氢,提出了采用单比对样品对H2S进行视觉二元检测的方法。选择溶液中发生的两种指示反应-形成稳定的MnS和CdS悬浮液。在硼酸缓冲液(pH 9.18)和明胶(稳定剂)存在下制备的悬浮液在24小时内是稳定的;在硫化氢归一化浓度(с m m = 15 mg L-1)附近,可以观察到悬浮液浊度的差异。在确定比较样品中H2S的浓度时,采用统计学方法;H2S (ccomp.)阈值的估计值小于该值的标准化水平,该值提供假阴性测试结果的风险不超过5% - MnS为11.6 mg L-1, cd为13.4 mg L-1。优先考虑基于稳定的cd悬浮液的测试系统,因为对于这种反应,不可靠的区间和ccomp值较窄。是更接近于价值的。用对苯二胺分光光度法对分析水样品中H2S进行目测二元检测的正确性进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.00
自引率
14.30%
发文量
12
期刊介绍: The journal "Methods and objects of chemical analysis" is peer-review journal and publishes original articles of theoretical and experimental analysis on topical issues and bio-analytical chemistry, chemical and pharmaceutical analysis, as well as chemical metrology. Submitted works shall cover the results of completed studies and shall make scientific contributions to the relevant area of expertise. The journal publishes review articles, research articles and articles related to latest developments of analytical instrumentations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信