{"title":"Settlement and tilt of low-rise buildings","authors":"J. Charles, H. D. Skinner","doi":"10.1680/GENG.2004.157.2.65","DOIUrl":null,"url":null,"abstract":"Where deep foundations are not an economically viable solution, foundation problems may occur at low-rise housing developments on poor ground. It is usually feasible to provide a raft foundation relatively cheaply for lightly loaded buildings. When differential settlement occurs, foundations of adequate stiffness will cause the building to tilt as a rigid body, and will prevent significant distortion of the building and consequent cracking of the walls. A number of case histories of tilted buildings are presented to illustrate the magnitude of tilt that has been observed with different ground conditions, and the remedial actions that have been undertaken. Noticeability is a key factor in assessing the acceptability of tilt for low-rise residential buildings and their occupants, and tilt typically is noticed when it is in the region of 1/250 to 1/200. Where tilts of the magnitude of 1/100 or greater are measured, or the measured rate of increase of tilt indicates that this degree of tilt will be exceeded, ...","PeriodicalId":45150,"journal":{"name":"Geotechnical Engineering","volume":"157 1","pages":"65-75"},"PeriodicalIF":0.3000,"publicationDate":"2004-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1680/GENG.2004.157.2.65","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geotechnical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1680/GENG.2004.157.2.65","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 32
Abstract
Where deep foundations are not an economically viable solution, foundation problems may occur at low-rise housing developments on poor ground. It is usually feasible to provide a raft foundation relatively cheaply for lightly loaded buildings. When differential settlement occurs, foundations of adequate stiffness will cause the building to tilt as a rigid body, and will prevent significant distortion of the building and consequent cracking of the walls. A number of case histories of tilted buildings are presented to illustrate the magnitude of tilt that has been observed with different ground conditions, and the remedial actions that have been undertaken. Noticeability is a key factor in assessing the acceptability of tilt for low-rise residential buildings and their occupants, and tilt typically is noticed when it is in the region of 1/250 to 1/200. Where tilts of the magnitude of 1/100 or greater are measured, or the measured rate of increase of tilt indicates that this degree of tilt will be exceeded, ...
期刊介绍:
The objectives of the Association shall be the promotion of co-operation among geotechnical societies in SE Asia; and the assistance to member societies who have limited number of members. Now there is only one combined web titled: AGSSEA-SEAGS. SEAGS & AGSSEA encourage the submission of scholarly and practice-oriented articles to its journal. The journal is published quarterly. Both sponsors of the journal, the Southeast Asian Geotechnical Society and the Association of Geotechnical Societies in Southeast Asia, promote the ideals and goals of the International Society of Soil Mechanics and Geotechhnical Engineering in fostering communications, developing insights and enabling the advancement of the geotechnical engineering discipline.