Endovascular repair of abdominal aortic aneurysm using a pararenal fenestrated stent-graft.

R. Faruqi, T. Chuter, L. Reilly, R. Sawhney, S. Wall, C. Canto, L. Messina
{"title":"Endovascular repair of abdominal aortic aneurysm using a pararenal fenestrated stent-graft.","authors":"R. Faruqi, T. Chuter, L. Reilly, R. Sawhney, S. Wall, C. Canto, L. Messina","doi":"10.1583/1074-6218(1999)006<0354:EROAAA>2.0.CO;2","DOIUrl":null,"url":null,"abstract":"Purpose:To report an unusual case of endovascular abdominal aortic aneurysm (AAA) exclusion in which a fenestrated stent-graft was used to seal a proximal Type I endoleak.Methods and Results:An 84-year-old man with a 6.0-cm AAA underwent an aortomonoiliac aneurysm exclusion procedure that was complicated by a proximal endoleak. Because the patient had no right kidney, an additional stent-graft was designed to cover the right renal artery stump while preserving left renal perfusion through a fenestration in the graft material. This approach was successful in obliterating the endoleak around the proximal attachment site, but flow through the lumbar arteries remained.Conclusions:The use of a fenestrated stent-graft is feasible, but the type of fenestration in this case has limited applicability owing to the rarity of patients with suitable anatomy.","PeriodicalId":79443,"journal":{"name":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"62","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1583/1074-6218(1999)006<0354:EROAAA>2.0.CO;2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 62

Abstract

Purpose:To report an unusual case of endovascular abdominal aortic aneurysm (AAA) exclusion in which a fenestrated stent-graft was used to seal a proximal Type I endoleak.Methods and Results:An 84-year-old man with a 6.0-cm AAA underwent an aortomonoiliac aneurysm exclusion procedure that was complicated by a proximal endoleak. Because the patient had no right kidney, an additional stent-graft was designed to cover the right renal artery stump while preserving left renal perfusion through a fenestration in the graft material. This approach was successful in obliterating the endoleak around the proximal attachment site, but flow through the lumbar arteries remained.Conclusions:The use of a fenestrated stent-graft is feasible, but the type of fenestration in this case has limited applicability owing to the rarity of patients with suitable anatomy.
应用肾旁开窗支架血管内修复腹主动脉瘤。
目的:报告一例不寻常的血管内腹主动脉瘤(AAA)排除病例,其中开窗支架移植用于封闭近端I型内漏。方法和结果:一名84岁的男性,6.0 cm AAA,接受了主动脉-腹髂动脉瘤排除手术,并伴有近端内漏。由于患者没有右肾,因此设计了一个额外的支架移植物来覆盖右肾动脉残端,同时通过移植物材料的开窗保留左肾灌注。该入路成功地消除了近端附着部位周围的内漏,但仍有血流通过腰椎动脉。结论:采用开窗支架移植是可行的,但由于具有合适解剖结构的患者很少,因此在本病例中开窗类型的适用性有限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信