Guide wire fracture with remnant filament in left circumflex artery and ascending aorta

K. Vichairuangthum
{"title":"Guide wire fracture with remnant filament in left circumflex artery and ascending aorta","authors":"K. Vichairuangthum","doi":"10.15406/MOJCR.2020.10.00363","DOIUrl":null,"url":null,"abstract":"Retained fractured coronary guide wire fragments are rarely encountered during percutaneous coronary intervention, but may cause fatal complication such as thrombosis, emboli, dissection and perforation. Management of retained fractured coronary guide wire depends upon the clinical situation of the patient and the position and length of the fractured guide wire remnant. This article present a case of remnant guide wire filaments that remained in aorta without complications.","PeriodicalId":93339,"journal":{"name":"MOJ clinical & medical case reports","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MOJ clinical & medical case reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15406/MOJCR.2020.10.00363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Retained fractured coronary guide wire fragments are rarely encountered during percutaneous coronary intervention, but may cause fatal complication such as thrombosis, emboli, dissection and perforation. Management of retained fractured coronary guide wire depends upon the clinical situation of the patient and the position and length of the fractured guide wire remnant. This article present a case of remnant guide wire filaments that remained in aorta without complications.
左旋动脉和升主动脉导丝断裂伴残丝
经皮冠状动脉介入治疗中,冠状动脉导丝碎片残留骨折的情况很少,但可能导致血栓形成、栓塞、夹层和穿孔等致命并发症。冠状动脉导丝骨折残留的处理取决于患者的临床情况和残余导丝骨折的位置和长度。本文报告一例主动脉内导丝残留无并发症的病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信