Analysis of Post-Combustion High-Strength Concrete Compressive Strength Using Polypropylene Fibers

T. B. Aulia, M. Muttaqin, M. Afifuddin, Z. Amalia
{"title":"Analysis of Post-Combustion High-Strength Concrete Compressive Strength Using Polypropylene Fibers","authors":"T. B. Aulia, M. Muttaqin, M. Afifuddin, Z. Amalia","doi":"10.14710/mkts.v26i1.28262","DOIUrl":null,"url":null,"abstract":"High-strength concrete is vulnerable to high temperatures due to its high density. The use of polypropylene fibers could prevent structure explosion by forming canals due to melted fibers during fire, thus release its thermal stress. This study aims to determine the effect of polypropylene fibers on compressive strength of high-strength concrete after combustion at 400ºC for five hours. High-strength concrete was made by w/c-ratio 0.3 with cement amount 550 kg/m3 and added with silica fume 8% and superplasticizer 4% by cement weight. The variations of polypropylene fibers were 0%, 0.2% and 0.4% of concrete volume. The compression test was carried out on standard cylinders Ø15/30 cm of combustion and without combustion specimens at 7 and 28 days. The results showed that compressive strength of high-strength concretes without using polypropylene fibers decreased in post-combustion compared with specimens without combustion, i.e., 0.81% at 7 days and 23.42% at 28 days. Conversely, the use of polypropylene fibers can increase post-combustion compressive strength with a maximum value resulted in adding 0.2% which are 25.52% and 10.44% at 7 and 28 days respectively. It can be concluded that the use of polypropylene fibers is effective to prevent reduction of high-strength concrete compressive strength that are burned at high temperatures.","PeriodicalId":31880,"journal":{"name":"Media Komunikasi Teknik Sipil","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Media Komunikasi Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/mkts.v26i1.28262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

High-strength concrete is vulnerable to high temperatures due to its high density. The use of polypropylene fibers could prevent structure explosion by forming canals due to melted fibers during fire, thus release its thermal stress. This study aims to determine the effect of polypropylene fibers on compressive strength of high-strength concrete after combustion at 400ºC for five hours. High-strength concrete was made by w/c-ratio 0.3 with cement amount 550 kg/m3 and added with silica fume 8% and superplasticizer 4% by cement weight. The variations of polypropylene fibers were 0%, 0.2% and 0.4% of concrete volume. The compression test was carried out on standard cylinders Ø15/30 cm of combustion and without combustion specimens at 7 and 28 days. The results showed that compressive strength of high-strength concretes without using polypropylene fibers decreased in post-combustion compared with specimens without combustion, i.e., 0.81% at 7 days and 23.42% at 28 days. Conversely, the use of polypropylene fibers can increase post-combustion compressive strength with a maximum value resulted in adding 0.2% which are 25.52% and 10.44% at 7 and 28 days respectively. It can be concluded that the use of polypropylene fibers is effective to prevent reduction of high-strength concrete compressive strength that are burned at high temperatures.
聚丙烯纤维燃烧后高强混凝土抗压强度分析
高强混凝土由于密度大,易受高温的影响。使用聚丙烯纤维可以防止结构爆炸,因为纤维在火灾中熔化形成管道,从而释放其热应力。本研究旨在确定聚丙烯纤维对高强混凝土在400℃下燃烧5小时后抗压强度的影响。高强度混凝土采用w/c比0.3,水泥用量550 kg/m3,硅灰掺量占水泥质量的8%,高效减水剂掺量占水泥质量的4%。聚丙烯纤维的掺量分别为混凝土体积的0%、0.2%和0.4%。压缩试验分别在标准气缸Ø15/30 cm燃烧和不含燃烧试样上进行,时间分别为7天和28天。结果表明:与未燃烧的高强混凝土相比,未使用聚丙烯纤维的高强混凝土燃烧后抗压强度在燃烧后7天下降0.81%,28天下降23.42%;相反,聚丙烯纤维的使用可以提高燃烧后抗压强度,添加量为0.2%时达到最大值,在第7天和第28天分别为25.52%和10.44%。可以得出结论,聚丙烯纤维的使用对防止高温燃烧的高强混凝土抗压强度降低是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书