A novel device for detection of soft tissue inflammation: dynamic behaviour of a functionally graded AFM cantilever

K. Firoozbakhsh, M. Ahmadian, M. Rahaeifard, M. Kahrobaiyan
{"title":"A novel device for detection of soft tissue inflammation: dynamic behaviour of a functionally graded AFM cantilever","authors":"K. Firoozbakhsh, M. Ahmadian, M. Rahaeifard, M. Kahrobaiyan","doi":"10.1504/IJECB.2012.049803","DOIUrl":null,"url":null,"abstract":"Atomic force microscopes (AFM) are devices used for surface roughness detection. A novel AFM device composed of a tip attached to a cantilever beam is proposed for precise soft-tissue-inflammation detection. It is assumed that the beam is made of functionally graded materials (FGMs) with properties varying throughout the thickness. Two low resonant frequencies and the sensitivities of the AFM cantilever are studied. A relationship is developed to evaluate the sensitivity of a FGM micro-cantilever beam. The effects of mass distributions of material constituents, surface contact stiffness, and geometric parameters on the resonant frequencies and sensitivities are studied. The high sensitivity of such device to the stiffness of the contact surface is proposed to be the recognition key for soft tissue inflammation.","PeriodicalId":90184,"journal":{"name":"International journal of experimental and computational biomechanics","volume":"2 1","pages":"1"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJECB.2012.049803","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of experimental and computational biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJECB.2012.049803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Atomic force microscopes (AFM) are devices used for surface roughness detection. A novel AFM device composed of a tip attached to a cantilever beam is proposed for precise soft-tissue-inflammation detection. It is assumed that the beam is made of functionally graded materials (FGMs) with properties varying throughout the thickness. Two low resonant frequencies and the sensitivities of the AFM cantilever are studied. A relationship is developed to evaluate the sensitivity of a FGM micro-cantilever beam. The effects of mass distributions of material constituents, surface contact stiffness, and geometric parameters on the resonant frequencies and sensitivities are studied. The high sensitivity of such device to the stiffness of the contact surface is proposed to be the recognition key for soft tissue inflammation.
一种用于检测软组织炎症的新装置:功能分级AFM悬臂的动态行为
原子力显微镜(AFM)是一种用于表面粗糙度检测的仪器。提出了一种新型的由附着在悬臂梁上的尖端组成的AFM装置,用于软组织炎症的精确检测。假设梁由功能梯度材料(fgm)制成,其性能在整个厚度范围内变化。研究了AFM悬臂梁的两种低谐振频率和灵敏度。建立了一个关系式来评价FGM微悬臂梁的灵敏度。研究了材料成分的质量分布、表面接触刚度和几何参数对谐振频率和灵敏度的影响。该装置对接触面刚度的高灵敏度被认为是软组织炎症的识别关键。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信