Can the Intracuff Pressure Be Estimated by Palpation of the Pilot Balloon

J. Bryant, J. Werner, E. Moss, J. Tobias
{"title":"Can the Intracuff Pressure Be Estimated by Palpation of the Pilot Balloon","authors":"J. Bryant, J. Werner, E. Moss, J. Tobias","doi":"10.1177/1944451613489310","DOIUrl":null,"url":null,"abstract":"Background. Over the past 5 years, there has been a change in the clinical practice of pediatric anesthesiology with a transition to the use of cuffed instead of uncuffed endotracheal tubes in infants and children. However, there has been limited attention to techniques to ensure a safe intracuff pressure. We sought to determine the accuracy of estimating endotracheal tube intracuff pressure by palpation of the pilot balloon by anesthesiologists, anesthesia residents, pediatric anesthesia fellows, certified nurse anesthetists, and student nurse anesthetists. Methods. A tracheal simulation model was constructed with 3 different diameters of polyvinylchloride tubing. Three different-sized endotracheal tubes (4.0, 5.0, and 6.0 mm) were then placed into the tubes and the cuffs inflated to various pressures. Each participant was given 3 different scenarios of cuff pressure for each endotracheal tube size for a total of 9 scenarios per practitioner. By feeling the pilot balloon, the anesthesia provider was aske...","PeriodicalId":89772,"journal":{"name":"ICU director","volume":"1 1","pages":"170-172"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1944451613489310","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICU director","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1944451613489310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background. Over the past 5 years, there has been a change in the clinical practice of pediatric anesthesiology with a transition to the use of cuffed instead of uncuffed endotracheal tubes in infants and children. However, there has been limited attention to techniques to ensure a safe intracuff pressure. We sought to determine the accuracy of estimating endotracheal tube intracuff pressure by palpation of the pilot balloon by anesthesiologists, anesthesia residents, pediatric anesthesia fellows, certified nurse anesthetists, and student nurse anesthetists. Methods. A tracheal simulation model was constructed with 3 different diameters of polyvinylchloride tubing. Three different-sized endotracheal tubes (4.0, 5.0, and 6.0 mm) were then placed into the tubes and the cuffs inflated to various pressures. Each participant was given 3 different scenarios of cuff pressure for each endotracheal tube size for a total of 9 scenarios per practitioner. By feeling the pilot balloon, the anesthesia provider was aske...
可通过触诊引航气囊来估计颅内压力吗
背景。在过去的5年里,儿科麻醉学的临床实践发生了变化,婴儿和儿童使用带手铐的气管内管取代了不带手铐的气管内管。然而,对于确保安全的颅内压力的技术关注有限。我们试图通过由麻醉师、麻醉住院医师、儿科麻醉研究员、注册麻醉师护士和麻醉师实习护士触诊引航气囊来确定估计气管内管腔内压力的准确性。方法。采用3种不同直径的聚氯乙烯管建立了气管仿真模型。然后将三根不同尺寸的气管内管(4.0、5.0和6.0 mm)放入管中,并将套管膨胀到不同的压力。每个参与者被给予3种不同的袖口压力情景,每种气管插管尺寸,每个医生总共有9种情景。通过感觉引航气球,麻醉提供者被要求……
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书