Cuffed Endotracheal Tubes in Infants and Children A Technique to Ensure an Acceptable Intracuff Pressure

J. Tobias, S. Gopalakrishnan, J. Rice, K. Jatana, Charles A. Elmaraghy, Meredith N. Merz
{"title":"Cuffed Endotracheal Tubes in Infants and Children A Technique to Ensure an Acceptable Intracuff Pressure","authors":"J. Tobias, S. Gopalakrishnan, J. Rice, K. Jatana, Charles A. Elmaraghy, Meredith N. Merz","doi":"10.1177/1944451612471190","DOIUrl":null,"url":null,"abstract":"Background. Over the past 5 to 10 years, there has been a change in the clinical practice of pediatric anesthesiology with a transition to the use of cuffed instead of uncuffed endotracheal tubes (ETTs) in infants and children. When such tubes are used in clinical practice, it is imperative to ensure that the intracuff pressure is ≤30 cm H2O. To date, there are limited data regarding techniques to ensure this practice. Methods. Following endotracheal intubation with a cuffed ETT, a stethoscope was placed in the sternal notch and continuous positive airway pressure of 20 to 25 cm H2O held. The fresh gas flow was increased as needed to achieve a gradual rise of the airway pressure. Using a syringe, air was added to the cuff until no air escape or leak was heard. The intracuff pressure was checked using a handheld manometer (Posey Cufflator Endotracheal Tube Inflator and Manometer, JT Posey Company, Arcadia, CA). Results. The cohort for the study included 200 patients ranging in age from 6 months to 18 years...","PeriodicalId":89772,"journal":{"name":"ICU director","volume":"140 1","pages":"62-64"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1944451612471190","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICU director","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1944451612471190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Background. Over the past 5 to 10 years, there has been a change in the clinical practice of pediatric anesthesiology with a transition to the use of cuffed instead of uncuffed endotracheal tubes (ETTs) in infants and children. When such tubes are used in clinical practice, it is imperative to ensure that the intracuff pressure is ≤30 cm H2O. To date, there are limited data regarding techniques to ensure this practice. Methods. Following endotracheal intubation with a cuffed ETT, a stethoscope was placed in the sternal notch and continuous positive airway pressure of 20 to 25 cm H2O held. The fresh gas flow was increased as needed to achieve a gradual rise of the airway pressure. Using a syringe, air was added to the cuff until no air escape or leak was heard. The intracuff pressure was checked using a handheld manometer (Posey Cufflator Endotracheal Tube Inflator and Manometer, JT Posey Company, Arcadia, CA). Results. The cohort for the study included 200 patients ranging in age from 6 months to 18 years...
婴儿和儿童带口气管插管:一种确保可接受的管内压力的技术
背景。在过去的5到10年里,儿科麻醉学的临床实践发生了变化,婴儿和儿童使用带手铐的气管内管取代了不带手铐的气管内管。在临床上使用此类管时,必须保证管内压力≤30cm H2O。迄今为止,关于确保这种做法的技术的数据有限。方法。用带袖口的ETT气管插管后,听诊器置于胸骨切口,持续气道正压20 ~ 25 cm H2O。根据需要增加新鲜气体流量,以实现气道压力的逐渐上升。使用注射器,空气被添加到袖带,直到没有空气逸出或泄漏的声音。使用手持式压力计(Posey Cufflator Endotracheal Tube Inflator and pressure ometer, JT Posey Company, Arcadia, CA)检查气道内压力。结果。这项研究的队列包括200名患者,年龄从6个月到18岁不等。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书