H. Wagner, Bjarne Madsen-Hardig, M. Rundgren, J. Harnek, Matthias Götberg, G. Olivecrona
{"title":"Cerebral Oximetry During Prolonged Cardiac Arrest and Percutaneous Coronary Intervention : A Report on Five Cases","authors":"H. Wagner, Bjarne Madsen-Hardig, M. Rundgren, J. Harnek, Matthias Götberg, G. Olivecrona","doi":"10.1177/1944451612469225","DOIUrl":null,"url":null,"abstract":"Objective. To evaluate the feasibility of cerebral oximetry (SctO2) with arterial blood pressure (ABP), central venous pressure (CVP), end tidal carbon dioxide (ETCO2), pulse oximetry (SpO2), and arterial blood gases during resuscitation in the coronary catheterization laboratory (cath-lab) setting. Design. We have implemented SctO2 in our cath-lab when cardiac arrest patients are in the need of prolonged resuscitation efforts with mechanical chest compressions (MCC) during simultaneous percutaneous coronary intervention (PCI). Setting. An academic coronary catheterization laboratory. Patients. Five cardiac arrest patients required prolonged resuscitation efforts with MCC in the cath-lab during simultaneous PCI. Results. During MCC, median SctO2 (n = 5) was 47%, median systolic ABP (n = 5) was 88 mm Hg, mean ABP (n = 5) was 58 mm Hg, coronary perfusion pressure (n = 3) was 19 mm Hg, SpO2 (n = 4) was 81%, and ETCO2 (n = 4) was 18.8 torr (2.5 kPa). Four patients had a successful PCI, including 1 patient wit...","PeriodicalId":89772,"journal":{"name":"ICU director","volume":"4 1","pages":"22-32"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1944451612469225","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICU director","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1944451612469225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Objective. To evaluate the feasibility of cerebral oximetry (SctO2) with arterial blood pressure (ABP), central venous pressure (CVP), end tidal carbon dioxide (ETCO2), pulse oximetry (SpO2), and arterial blood gases during resuscitation in the coronary catheterization laboratory (cath-lab) setting. Design. We have implemented SctO2 in our cath-lab when cardiac arrest patients are in the need of prolonged resuscitation efforts with mechanical chest compressions (MCC) during simultaneous percutaneous coronary intervention (PCI). Setting. An academic coronary catheterization laboratory. Patients. Five cardiac arrest patients required prolonged resuscitation efforts with MCC in the cath-lab during simultaneous PCI. Results. During MCC, median SctO2 (n = 5) was 47%, median systolic ABP (n = 5) was 88 mm Hg, mean ABP (n = 5) was 58 mm Hg, coronary perfusion pressure (n = 3) was 19 mm Hg, SpO2 (n = 4) was 81%, and ETCO2 (n = 4) was 18.8 torr (2.5 kPa). Four patients had a successful PCI, including 1 patient wit...