Data Quality Associated with Handwritten Laboratory Test Requests: Classification and Frequency of Data-Entry Errors for Outpatient Serology Tests

IF 2.7 3区 医学 Q2 HEALTH POLICY & SERVICES
E. Vecellio, M. Maley, G. Toouli, A. Georgiou, J. Westbrook
{"title":"Data Quality Associated with Handwritten Laboratory Test Requests: Classification and Frequency of Data-Entry Errors for Outpatient Serology Tests","authors":"E. Vecellio, M. Maley, G. Toouli, A. Georgiou, J. Westbrook","doi":"10.1177/183335831504400302","DOIUrl":null,"url":null,"abstract":"Objective: Manual data-entry of handwritten laboratory test requests into electronic information systems has implications for data accuracy. This study sought to identify the types and number of errors occurring for handwritten serology test requests received from outpatient clinics. Methods: A 15-day audit at a serology laboratory in Sydney, Australia, compared the content of all transcribed serology outpatient test requests in the laboratory information system with the handwritten request form. Results: One or more errors were detected in 67/627 (10.7%) audited requests (N=68 errors). Fifty-one of the errors (75.0%) were transcription errors: the wrong test was transcribed in 40/68 cases (58.8%) – ten of these occurred when the abbreviations ‘HBsAb’ and ‘HBsAg’ were confounded for one another – and transcribed requests were missing a test in 11/68 cases (16.2%). The remaining 17 non-transcription errors (25.0%) described request forms not signed by the ordering clinician, mislabelled specimens, and wrong tests due to computer algorithm errors. Conclusions: Manual data-entry of handwritten serology requests is an error-prone process. Electronic ordering has the potential to eliminate illegible handwriting and transcription errors, thus improving data accuracy in hospital information systems.","PeriodicalId":55068,"journal":{"name":"Health Information Management Journal","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/183335831504400302","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health Information Management Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/183335831504400302","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH POLICY & SERVICES","Score":null,"Total":0}
引用次数: 2

Abstract

Objective: Manual data-entry of handwritten laboratory test requests into electronic information systems has implications for data accuracy. This study sought to identify the types and number of errors occurring for handwritten serology test requests received from outpatient clinics. Methods: A 15-day audit at a serology laboratory in Sydney, Australia, compared the content of all transcribed serology outpatient test requests in the laboratory information system with the handwritten request form. Results: One or more errors were detected in 67/627 (10.7%) audited requests (N=68 errors). Fifty-one of the errors (75.0%) were transcription errors: the wrong test was transcribed in 40/68 cases (58.8%) – ten of these occurred when the abbreviations ‘HBsAb’ and ‘HBsAg’ were confounded for one another – and transcribed requests were missing a test in 11/68 cases (16.2%). The remaining 17 non-transcription errors (25.0%) described request forms not signed by the ordering clinician, mislabelled specimens, and wrong tests due to computer algorithm errors. Conclusions: Manual data-entry of handwritten serology requests is an error-prone process. Electronic ordering has the potential to eliminate illegible handwriting and transcription errors, thus improving data accuracy in hospital information systems.
与手写实验室测试请求相关的数据质量:门诊血清学测试数据输入错误的分类和频率
目的:手工数据输入手写实验室测试请求到电子信息系统有数据准确性的影响。本研究旨在确定从门诊收到的手写血清学测试请求发生的错误类型和数量。方法:对澳大利亚悉尼一家血清学实验室进行为期15天的审核,将实验室信息系统中所有血清学门诊检测请求的转录内容与手写请求表进行比较。结果:在67/627(10.7%)个审计请求(N=68)中检测到一个或多个错误。51个错误(75.0%)是转录错误:40/68例(58.8%)中转录错误的测试-其中10例发生在缩写“HBsAb”和“HBsAg”相互混淆时-转录请求缺失11/68例(16.2%)。其余17个非转录错误(25.0%)描述了下单临床医生未签署的请求表格、错误标记的标本以及由于计算机算法错误而导致的错误测试。结论:手工录入血清学手写请求是一个容易出错的过程。电子订购有可能消除难以辨认的笔迹和转录错误,从而提高医院信息系统的数据准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Health Information Management Journal
Health Information Management Journal 医学-医学:信息
CiteScore
8.70
自引率
12.50%
发文量
17
审稿时长
>12 weeks
期刊介绍: The Health Information Management Journal (HIMJ) is the official peer-reviewed research journal of the Health Information Management Association of Australia (HIMAA). HIMJ provides a forum for dissemination of original investigations and reviews covering a broad range of topics related to the management and communication of health information including: clinical and administrative health information systems at international, national, hospital and health practice levels; electronic health records; privacy and confidentiality; health classifications and terminologies; health systems, funding and resources management; consumer health informatics; public and population health information management; information technology implementation and evaluation and health information management education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信