Electronics for Whole-Body Liquid Scintillation Counters

R. Hiebert, J. Gallagher
{"title":"Electronics for Whole-Body Liquid Scintillation Counters","authors":"R. Hiebert, J. Gallagher","doi":"10.1109/TBMEL.1962.4322950","DOIUrl":null,"url":null,"abstract":"Large liquid scintillation counters offer a unique combination of high sensitivity and moderate energy resolution and hence are particularly useful for the rapid measurement of the radioactivity of the human body and other large samples. This counter permits measurements of internal gamma contamination of the human body at concentrations 1000 times less than maximum permissible levels. Such an instrument can, therefore, have many practical applications to diagnosis in clinical and experimental medicine. The instrumentation to be described is used with the new Los Alamos human counter but the techniques are applicable to large liquid scintillation counters in general. Objectives in this system are: 1) optimizing pulse-height (energy) resolution from the detector, 2) optimizing SNR, 3) long-term stability and freedom from rate and overload deficiencies and 4) accuracy, speed and versatility of data handling and processing.","PeriodicalId":86470,"journal":{"name":"IRE transactions on bio-medical electronics","volume":"37 1","pages":"54-61"},"PeriodicalIF":0.0000,"publicationDate":"1962-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TBMEL.1962.4322950","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IRE transactions on bio-medical electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBMEL.1962.4322950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Large liquid scintillation counters offer a unique combination of high sensitivity and moderate energy resolution and hence are particularly useful for the rapid measurement of the radioactivity of the human body and other large samples. This counter permits measurements of internal gamma contamination of the human body at concentrations 1000 times less than maximum permissible levels. Such an instrument can, therefore, have many practical applications to diagnosis in clinical and experimental medicine. The instrumentation to be described is used with the new Los Alamos human counter but the techniques are applicable to large liquid scintillation counters in general. Objectives in this system are: 1) optimizing pulse-height (energy) resolution from the detector, 2) optimizing SNR, 3) long-term stability and freedom from rate and overload deficiencies and 4) accuracy, speed and versatility of data handling and processing.
用于全身液体闪烁计数器的电子器件
大型液体闪烁计数器提供了高灵敏度和中等能量分辨率的独特组合,因此对于人体和其他大型样品的放射性的快速测量特别有用。该计数器允许在低于最大允许水平1000倍的浓度下测量人体内部伽马污染。因此,这种仪器可以在临床和实验医学诊断中有许多实际应用。所描述的仪器与新的洛斯阿拉莫斯人类计数器一起使用,但这些技术一般适用于大型液体闪烁计数器。该系统的目标是:1)优化探测器的脉冲高度(能量)分辨率,2)优化信噪比,3)长期稳定,不受速率和过载缺陷的影响,4)数据处理和处理的准确性、速度和通用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信