{"title":"Hybrid Experimental-Computational Approach for Solder/IMC Interface Shear Strength Determination in Solder Joints","authors":"M. Tamin, F. M. Nor, W. K. Loh","doi":"10.1109/TCAPT.2010.2050887","DOIUrl":null,"url":null,"abstract":"Damage-based models for solder/intermetallics (IMC) interface often require the interface properties such as tensile and shear strengths. The minute size of the solder joint renders direct experimental determination of these properties impractical. This paper presents a hybrid experimental-computational approach to determine the shear strength of solder/IMC interface. Displacement-controlled ball shear tests are performed on as-reflowed and thermally-aged solder specimens. The observed sudden load drop in the load-displacement curve corresponds to the crack initiation event and the load is indicative of the shear strength of the solder/IMC interface. Finite element simulation of the ball shear test is then employed to establish the complex stress states at the interface corresponding to the onset of fracture. The finite element model consists of Sn40Pb solder, Ni3Sn4 intermetallic and Ni layers, copper pad and a rigid shear tool. Unified inelastic strain theory describes the strain rate-dependent response of the solder while other materials are assumed to behave elastically. Quasi-static ball shear test is simulated at 30°C with a prescribed displacement rate of 0.5mm/min. Results show that steep stress gradients develop in the shear tool-solder contact and solder/IMC interface regions indicating effective load transfer to the interface. The bending (normal) stress is found to be of the same order of magnitude as the maximum shear stress. Higher stress values are predicted near the leading edge of the solder/IMC interface. The equivalent shear stress condition to the triaxial stress state at the interface, represented by the absolute maximum shear stress, τmax,abs should have reached the shear strength of the interface at fracture. The resulting shear strength of Sn40Pb/Ni3Sn4 interface is determined to be 87.5 MPa.","PeriodicalId":55013,"journal":{"name":"IEEE Transactions on Components and Packaging Technologies","volume":"33 1","pages":"614-620"},"PeriodicalIF":0.0000,"publicationDate":"2010-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TCAPT.2010.2050887","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Components and Packaging Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TCAPT.2010.2050887","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Damage-based models for solder/intermetallics (IMC) interface often require the interface properties such as tensile and shear strengths. The minute size of the solder joint renders direct experimental determination of these properties impractical. This paper presents a hybrid experimental-computational approach to determine the shear strength of solder/IMC interface. Displacement-controlled ball shear tests are performed on as-reflowed and thermally-aged solder specimens. The observed sudden load drop in the load-displacement curve corresponds to the crack initiation event and the load is indicative of the shear strength of the solder/IMC interface. Finite element simulation of the ball shear test is then employed to establish the complex stress states at the interface corresponding to the onset of fracture. The finite element model consists of Sn40Pb solder, Ni3Sn4 intermetallic and Ni layers, copper pad and a rigid shear tool. Unified inelastic strain theory describes the strain rate-dependent response of the solder while other materials are assumed to behave elastically. Quasi-static ball shear test is simulated at 30°C with a prescribed displacement rate of 0.5mm/min. Results show that steep stress gradients develop in the shear tool-solder contact and solder/IMC interface regions indicating effective load transfer to the interface. The bending (normal) stress is found to be of the same order of magnitude as the maximum shear stress. Higher stress values are predicted near the leading edge of the solder/IMC interface. The equivalent shear stress condition to the triaxial stress state at the interface, represented by the absolute maximum shear stress, τmax,abs should have reached the shear strength of the interface at fracture. The resulting shear strength of Sn40Pb/Ni3Sn4 interface is determined to be 87.5 MPa.
锡料/IMC界面抗剪强度测定的混合实验-计算方法
基于损伤的焊料/金属间化合物(IMC)界面模型通常需要界面性能,如拉伸和剪切强度。焊点的微小尺寸使得这些特性的直接实验测定不切实际。本文提出了一种混合实验-计算方法来确定焊料/IMC界面的抗剪强度。位移控制球剪切试验是在回流焊和热时效焊料试样上进行的。在载荷-位移曲线中观察到的载荷突然下降与裂纹萌生事件相对应,载荷指示了钎料/IMC界面的抗剪强度。然后采用球剪试验的有限元模拟,建立了界面处与断裂起始点相对应的复杂应力状态。有限元模型由Sn40Pb焊料、Ni3Sn4金属间化合物和Ni层、铜垫和刚性剪切工具组成。统一的非弹性应变理论描述了焊料的应变率相关响应,而其他材料被认为是弹性的。模拟准静态球剪试验,温度为30℃,规定位移速率为0.5mm/min。结果表明,在剪切工具-焊料接触区域和焊料/IMC界面区域出现陡峭的应力梯度,表明载荷有效传递到界面。发现弯曲(法向)应力与最大剪应力具有相同的数量级。预计在钎料/IMC界面的前缘附近会有较高的应力值。等效剪切应力条件为界面处三轴应力状态,以绝对最大剪切应力τmax,abs表示,应达到界面断裂时的剪切强度。所得Sn40Pb/Ni3Sn4界面抗剪强度为87.5 MPa。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书