{"title":"Direct Measurement of the Loss Conductance of Condensers at High Frequencies","authors":"M. Boella","doi":"10.1109/JRPROC.1938.228310","DOIUrl":null,"url":null,"abstract":"A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.","PeriodicalId":54574,"journal":{"name":"Proceedings of the Institute of Radio Engineers","volume":"26 1","pages":"421-432"},"PeriodicalIF":0.0000,"publicationDate":"1938-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228310","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institute of Radio Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JRPROC.1938.228310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A method of measuring the losses of a variable air condenser at high frequencies is described in which the condenser under test and the standard are connected in series as part of a tuned circuit. A radio-frequency voltage of resonant frequency is impressed on this circuit for a stated value of the standard. The unknown is then removed and the standard adjusted to resonance. The voltage across the tuned circuit is readjusted to its initial value by placing a conductance across the standard. The design of the standard condenser requires special considerations which are discussed. A self-biasing valve voltmeter, which is not critical to variations in power-supply voltage, is used. The results of measurements on several specimen condensers are given. A method of extending the measurements to higher frequencies is shown.