Parallel-Resonance Methods for Precise Measurements of High Impedances at Radio Frequencies and a Comparison with the Ordinary Series-Resonance Methods

D. B. Sinclair
{"title":"Parallel-Resonance Methods for Precise Measurements of High Impedances at Radio Frequencies and a Comparison with the Ordinary Series-Resonance Methods","authors":"D. B. Sinclair","doi":"10.1109/JRPROC.1938.228188","DOIUrl":null,"url":null,"abstract":"Two parallel-resonance methods are described which determine primarily the parallel conductance of a parallel-tuned circuit. They are most useful for measuring relatively low admittances (high impedances). Since they are duals of the reactance- and resistance-variation methods, they have been named the susceptance- and conductance-variation methods. These parallel-resonance methods are compared with the series-resonance methods with respect to range and possible sources of error. It is pointed out that, for substitution measurements, tight coupling to a constant-frequency power source need not introduce errors in measurements with either series- or parallel-resonance methods. The errors caused by residual inductance and metallic and dielectric loss in the standard condenser are discussed and numerical examples given. A precise method of interpreting resonance-curve data is presented. Experimental results are listed for measurements of high resistances by the susceptance-variation method.","PeriodicalId":54574,"journal":{"name":"Proceedings of the Institute of Radio Engineers","volume":"26 1","pages":"1466-1497"},"PeriodicalIF":0.0000,"publicationDate":"1938-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/JRPROC.1938.228188","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institute of Radio Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JRPROC.1938.228188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Two parallel-resonance methods are described which determine primarily the parallel conductance of a parallel-tuned circuit. They are most useful for measuring relatively low admittances (high impedances). Since they are duals of the reactance- and resistance-variation methods, they have been named the susceptance- and conductance-variation methods. These parallel-resonance methods are compared with the series-resonance methods with respect to range and possible sources of error. It is pointed out that, for substitution measurements, tight coupling to a constant-frequency power source need not introduce errors in measurements with either series- or parallel-resonance methods. The errors caused by residual inductance and metallic and dielectric loss in the standard condenser are discussed and numerical examples given. A precise method of interpreting resonance-curve data is presented. Experimental results are listed for measurements of high resistances by the susceptance-variation method.
射频高阻抗精确测量的并联谐振方法及其与普通串联谐振方法的比较
描述了两种并联谐振方法,它们主要确定并联调谐电路的并联电导。它们最适用于测量相对低导纳(高阻抗)。由于它们是电抗变分法和电阻变分法的对偶,因此被称为电纳变分法和电导变分法。在误差范围和可能的误差来源方面,将这些并联谐振方法与串联谐振方法进行了比较。指出,在替代测量中,与恒频电源的紧密耦合不会给串联或并联谐振测量带来误差。讨论了标准电容器中残余电感、金属损耗和介质损耗引起的误差,并给出了数值算例。提出了一种解释共振曲线数据的精确方法。给出了用电纳变分法测量高电阻的实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信