Are nonlinear ventricular arrhythmia characteristics lost, as signal duration decreases?

R. Povinelli, F. M. Roberts, Michael T. Johnson, K. Ropella
{"title":"Are nonlinear ventricular arrhythmia characteristics lost, as signal duration decreases?","authors":"R. Povinelli, F. M. Roberts, Michael T. Johnson, K. Ropella","doi":"10.1109/CIC.2002.1166747","DOIUrl":null,"url":null,"abstract":"A novel, nonlinear, phase space based method to quickly and accurately identify life-threatening arrhythmias is proposed. The accuracy of the proposed method in identifying sinus rhythm (SR), monomorphic ventricular tachycardia (MVT), polymorphic VT (PVT), and ventricular fibrillation (VF) for signals of at least 0.5 s duration was determined for six different ECG signal lengths. The ECG recordings were transformed into a phase space, and statistical features of the resulting attractors were learned using artificial neural networks. Classification accuracies for SR, MVT, PVT and VF were 93-96, 95-100, 79-91, and 81-88%, respectively. As expected, classification accuracy for the proposed method was essentially equivalent for ECG signals longer than 1 s. Surprisingly, classification accuracy for this new method did not degrade for 0.5 s ECG signals, indicating that even such short duration signals contain structures predictive of rhythm type. The phase space method's classification accuracy was higher for all segment durations compared to two other methods.","PeriodicalId":80984,"journal":{"name":"Computers in cardiology","volume":"87 1","pages":"221-224"},"PeriodicalIF":0.0000,"publicationDate":"2002-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/CIC.2002.1166747","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2002.1166747","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

A novel, nonlinear, phase space based method to quickly and accurately identify life-threatening arrhythmias is proposed. The accuracy of the proposed method in identifying sinus rhythm (SR), monomorphic ventricular tachycardia (MVT), polymorphic VT (PVT), and ventricular fibrillation (VF) for signals of at least 0.5 s duration was determined for six different ECG signal lengths. The ECG recordings were transformed into a phase space, and statistical features of the resulting attractors were learned using artificial neural networks. Classification accuracies for SR, MVT, PVT and VF were 93-96, 95-100, 79-91, and 81-88%, respectively. As expected, classification accuracy for the proposed method was essentially equivalent for ECG signals longer than 1 s. Surprisingly, classification accuracy for this new method did not degrade for 0.5 s ECG signals, indicating that even such short duration signals contain structures predictive of rhythm type. The phase space method's classification accuracy was higher for all segment durations compared to two other methods.
随着信号持续时间的减少,非线性室性心律失常特征是否消失?
提出了一种新的、非线性的、基于相空间的快速准确识别危及生命的心律失常的方法。在6种不同的心电信号长度下,对持续时间至少为0.5 s的信号,确定该方法识别窦性心律(SR)、单形态室性心动过速(MVT)、多形态室性心动过速(PVT)和心室颤动(VF)的准确性。将心电记录转换成相空间,利用人工神经网络学习吸引子的统计特征。SR、MVT、PVT和VF的分类准确率分别为93 ~ 96、95 ~ 100、79 ~ 91和81 ~ 88%。正如预期的那样,对于超过1秒的心电信号,该方法的分类精度基本相同。令人惊讶的是,这种新方法的分类精度在0.5 s的ECG信号中没有下降,这表明即使是如此短的持续时间信号也包含预测节律类型的结构。相空间法在所有分段持续时间内的分类精度均高于其他两种方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信