The added value of lung perfusion scintigraphy semiquantitative measures in post-COVID patients with persistent dyspnea without pulmonary embolism.

Expert review of medical devices Pub Date : 2023-07-01 Epub Date: 2023-11-24 DOI:10.1080/17434440.2023.2277236
Francesco Lanfranchi, Sara Maggio, Carlo Delucchi, Francesca Bertoldi, Ferdinando Corica, Maria Silvia De Feo, Cecilia Marini, Teresita Aloè, Viviana Frantellizzi, Giuseppe De Vincentis, Silvia Morbelli, Gianmario Sambuceti, Emanuela Barisione, Matteo Bauckneht
{"title":"The added value of lung perfusion scintigraphy semiquantitative measures in post-COVID patients with persistent dyspnea without pulmonary embolism.","authors":"Francesco Lanfranchi, Sara Maggio, Carlo Delucchi, Francesca Bertoldi, Ferdinando Corica, Maria Silvia De Feo, Cecilia Marini, Teresita Aloè, Viviana Frantellizzi, Giuseppe De Vincentis, Silvia Morbelli, Gianmario Sambuceti, Emanuela Barisione, Matteo Bauckneht","doi":"10.1080/17434440.2023.2277236","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Persistent dyspnea is frequent in post-COVID patients, even in the absence of pulmonary embolism (PE). In this scenario, the role of lung perfusion scintigraphy is unclear. The present study correlated scintigraphy-based semiquantitative perfusion parameters with chest high-resolution computed tomography (hrCT) volumetric indexes and clinical data in post-COVID patients with persistent dyspnea.</p><p><strong>Research design and methods: </strong>Sixty patients (30 post-COVID and 30 not previously affected by COVID-19) with persistent dyspnea submitted to lung perfusion scintigraphy and hrCT were retrospectively recruited. Perfusion rates of the pulmonary fields and hrCT-based normalized inflated, emphysematous, infiltrated, collapsed, and vascular lung volumes were calculated. Inflammatory and coagulation biomarkers were collected. PE at imaging was an exclusion criterion.</p><p><strong>Results: </strong>Compared to controls, reduced perfusion rates of the lower pulmonary fields and higher perfusion rates of the middle ones were observed in post-COVID patients, while hrCT findings were superimposable between the two groups. Perfusion rates of lower pulmonary fields were significantly associated only with abnormal lung volumes at hrCT.</p><p><strong>Conclusions: </strong>In post-COVID dyspnea without PE, lung perfusion scintigraphy may reveal a pulmonary involvement not detectable by hrCT. Post-COVID patients may show decreased perfusion rates of lower pulmonary fields in the presence of normal vascular density and markers of inflammation/coagulation.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2277236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Persistent dyspnea is frequent in post-COVID patients, even in the absence of pulmonary embolism (PE). In this scenario, the role of lung perfusion scintigraphy is unclear. The present study correlated scintigraphy-based semiquantitative perfusion parameters with chest high-resolution computed tomography (hrCT) volumetric indexes and clinical data in post-COVID patients with persistent dyspnea.

Research design and methods: Sixty patients (30 post-COVID and 30 not previously affected by COVID-19) with persistent dyspnea submitted to lung perfusion scintigraphy and hrCT were retrospectively recruited. Perfusion rates of the pulmonary fields and hrCT-based normalized inflated, emphysematous, infiltrated, collapsed, and vascular lung volumes were calculated. Inflammatory and coagulation biomarkers were collected. PE at imaging was an exclusion criterion.

Results: Compared to controls, reduced perfusion rates of the lower pulmonary fields and higher perfusion rates of the middle ones were observed in post-COVID patients, while hrCT findings were superimposable between the two groups. Perfusion rates of lower pulmonary fields were significantly associated only with abnormal lung volumes at hrCT.

Conclusions: In post-COVID dyspnea without PE, lung perfusion scintigraphy may reveal a pulmonary involvement not detectable by hrCT. Post-COVID patients may show decreased perfusion rates of lower pulmonary fields in the presence of normal vascular density and markers of inflammation/coagulation.

肺灌注闪烁扫描半定量测量在无肺栓塞的持续性呼吸困难的新冠肺炎后患者中的附加值。
研究设计和方法:回顾性招募了60名接受肺灌注闪烁扫描和hrCT检查的持续呼吸困难患者(30名新冠肺炎后患者和30名未受新冠肺炎影响的患者)。计算肺野和基于hrCT的标准化充气、肺气肿、浸润、塌陷和血管肺体积的灌注率。收集炎症和凝血生物标志物。影像学检查时PE为排除标准。结果:与对照组相比,在新冠肺炎后患者中,观察到较低肺野的灌注率降低,中间肺野的灌流率升高,而hrCT结果在两组之间是重叠的。低肺野的灌注率仅与hrCT检查时的异常肺容量显著相关。结论:在没有PE的新冠肺炎后呼吸困难中,肺灌注闪烁扫描可能显示hrCT无法检测到的肺部受累。在存在正常血管密度和炎症/凝血标志物的情况下,新冠肺炎后患者可能表现出较低肺野的灌注率降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信