{"title":"The use of Q-switched alexandrite laser (755 nm, 100 ns) for eyeliner tattoo removal.","authors":"G. Moreno-Arias, A. Camps‐Fresneda","doi":"10.1080/14628839950516968","DOIUrl":null,"url":null,"abstract":"BACKGROUND Eyelid tattooing for cosmetic reasons has increased in the past few years, and unsatisfied customers may request pigment removal. Q-switched laser systems have been useful in these cases. OBJECTIVE To evaluate the clinical result of a patient with a bluish-black eyelid tattoo treated with Q-switched alexandrite laser. METHODS Threshold fluence was determined and a spot test made on the first visit. Treatment was with QSAL, with a fluence range of 6.75-7.50 J/cm2 (mean fluence 7.125 +/- 0.26) and overlapping +/- 10% at 4-week intervals. RESULTS The eyeliner tattoo was not completely removed after five treatments with QSAL, but noticeable pigment lightening was obtained. No side effects were seen. CONCLUSIONS Q-switched alexandrite laser may be a useful device to remove the bluish-black pigment used in cosmetic eyeliner tattoo.","PeriodicalId":81650,"journal":{"name":"Journal of cutaneous laser therapy","volume":"1 2 1","pages":"113-5"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/14628839950516968","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cutaneous laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14628839950516968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
BACKGROUND Eyelid tattooing for cosmetic reasons has increased in the past few years, and unsatisfied customers may request pigment removal. Q-switched laser systems have been useful in these cases. OBJECTIVE To evaluate the clinical result of a patient with a bluish-black eyelid tattoo treated with Q-switched alexandrite laser. METHODS Threshold fluence was determined and a spot test made on the first visit. Treatment was with QSAL, with a fluence range of 6.75-7.50 J/cm2 (mean fluence 7.125 +/- 0.26) and overlapping +/- 10% at 4-week intervals. RESULTS The eyeliner tattoo was not completely removed after five treatments with QSAL, but noticeable pigment lightening was obtained. No side effects were seen. CONCLUSIONS Q-switched alexandrite laser may be a useful device to remove the bluish-black pigment used in cosmetic eyeliner tattoo.