Qi Chen, Yi-Bang Cheng, Meng Shen, Bin Yin, H. Yi, Jing Feng, Min Li, Qing-Yun Li, Yan Li, Ji-Guang Wang
{"title":"A randomized controlled trial on ambulatory blood pressure lowering effect of CPAP in patients with obstructive sleep apnea and nocturnal hypertension","authors":"Qi Chen, Yi-Bang Cheng, Meng Shen, Bin Yin, H. Yi, Jing Feng, Min Li, Qing-Yun Li, Yan Li, Ji-Guang Wang","doi":"10.1080/08037051.2019.1686343","DOIUrl":null,"url":null,"abstract":"Abstract Objective: In a randomised controlled trial, we investigated the blood pressure (BP) lowering effect of continuous positive airway pressure (CPAP) in patients with moderate-severe obstructive sleep apnoea syndrome (OSAS, an apnoea-hypopnoea index, AHI of 15 or higher) and nocturnal hypertension (night-time systolic/diastolic BP ≥120/70 mmHg). Methods: Sixty patients were randomly assigned to CPAP or sham CPAP, while maintaining their antihypertensive treatment. Ambulatory BP monitoring was performed at baseline (first run-in visit) and the end of follow-up. Clinic and home BP were measured at baseline and each of the monthly follow-up visits. Results: Of the 60 patients, 47 completed the 3-month study. CPAP (n = 26), compared with sham CPAP (n = 21), slightly and non-significantly reduced 24-h systolic/diastolic BP by −2.8/−2.5 mmHg (p ≥ 0.27), with a slightly greater between-group difference in the daytime (−4.0/−2.8 mmHg, p ≥ 0.29) than night-time (−0.2/−1.5 mmHg, p ≥ 0.50). The CPAP treatment did not significantly influence clinic or home BP during follow-up (p ≥ 0.27). Nonetheless, simple and partial correlation analyses showed that the ambulatory BP lowering effect was dependent on the daytime pulse rate at baseline (r ≥ 0.47, p ≤ 0.01). In patients with a daytime pulse rate greater than 85 beats/min, the mean changes in daytime systolic BP were significantly greater in the CPAP (n = 10) than sham CPAP group (n = 11), with a between-group mean difference of −10.1 mmHg (p = 0.048). Conclusions: The CPAP treatment did not show significant ambulatory BP lowering effect in patients with moderate-severe OSAS and nocturnal hypertension. However, it may be effective in lowering daytime BP in patients with a faster pulse rate.","PeriodicalId":55591,"journal":{"name":"Blood Pressure","volume":"82 1","pages":"21 - 30"},"PeriodicalIF":2.3000,"publicationDate":"2019-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08037051.2019.1686343","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08037051.2019.1686343","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 8
Abstract
Abstract Objective: In a randomised controlled trial, we investigated the blood pressure (BP) lowering effect of continuous positive airway pressure (CPAP) in patients with moderate-severe obstructive sleep apnoea syndrome (OSAS, an apnoea-hypopnoea index, AHI of 15 or higher) and nocturnal hypertension (night-time systolic/diastolic BP ≥120/70 mmHg). Methods: Sixty patients were randomly assigned to CPAP or sham CPAP, while maintaining their antihypertensive treatment. Ambulatory BP monitoring was performed at baseline (first run-in visit) and the end of follow-up. Clinic and home BP were measured at baseline and each of the monthly follow-up visits. Results: Of the 60 patients, 47 completed the 3-month study. CPAP (n = 26), compared with sham CPAP (n = 21), slightly and non-significantly reduced 24-h systolic/diastolic BP by −2.8/−2.5 mmHg (p ≥ 0.27), with a slightly greater between-group difference in the daytime (−4.0/−2.8 mmHg, p ≥ 0.29) than night-time (−0.2/−1.5 mmHg, p ≥ 0.50). The CPAP treatment did not significantly influence clinic or home BP during follow-up (p ≥ 0.27). Nonetheless, simple and partial correlation analyses showed that the ambulatory BP lowering effect was dependent on the daytime pulse rate at baseline (r ≥ 0.47, p ≤ 0.01). In patients with a daytime pulse rate greater than 85 beats/min, the mean changes in daytime systolic BP were significantly greater in the CPAP (n = 10) than sham CPAP group (n = 11), with a between-group mean difference of −10.1 mmHg (p = 0.048). Conclusions: The CPAP treatment did not show significant ambulatory BP lowering effect in patients with moderate-severe OSAS and nocturnal hypertension. However, it may be effective in lowering daytime BP in patients with a faster pulse rate.
期刊介绍:
For outstanding coverage of the latest advances in hypertension research, turn to Blood Pressure, a primary source for authoritative and timely information on all aspects of hypertension research and management.
Features include:
• Physiology and pathophysiology of blood pressure regulation
• Primary and secondary hypertension
• Cerebrovascular and cardiovascular complications of hypertension
• Detection, treatment and follow-up of hypertension
• Non pharmacological and pharmacological management
• Large outcome trials in hypertension.