Characteristics of the audiometric notch as a clinical sign of noise exposure

D. McBride, S. Williams
{"title":"Characteristics of the audiometric notch as a clinical sign of noise exposure","authors":"D. McBride, S. Williams","doi":"10.1080/010503901300112211","DOIUrl":null,"url":null,"abstract":"This study investigated variability in audiometric notch recognition by asking three clinicians to identify notches in the audiograms of 634 noise-exposed employees. Agreement between the raters was assessed, and three notch characteristics, frequency, depth and shape (a wide or narrow notch), were investigated as recognition factors. The proportions of positive tests reported by each rater were 0.26, 0.49 and 0.68, respectively. The 'all rater' index of agreement was 0.45, and the range for pairwise comparisons was 0.14 to 0.52. With recognition factors, rater 1 was most strongly influenced by depth, rater 2 by shape and rater 3 by a possible combination of criteria. To reduce variability we suggest that narrow notches should be at least 15 dB in depth, and that broad notches should have a depth of 20 dB, with a recovery of at least 10 dB at the high end. Care should also be taken to elicit a sufficient history of noise exposure, and ensure that there are no other explanations for the notch.","PeriodicalId":76516,"journal":{"name":"Scandinavian audiology","volume":"30 1","pages":"106 - 111"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/010503901300112211","citationCount":"40","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/010503901300112211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 40

Abstract

This study investigated variability in audiometric notch recognition by asking three clinicians to identify notches in the audiograms of 634 noise-exposed employees. Agreement between the raters was assessed, and three notch characteristics, frequency, depth and shape (a wide or narrow notch), were investigated as recognition factors. The proportions of positive tests reported by each rater were 0.26, 0.49 and 0.68, respectively. The 'all rater' index of agreement was 0.45, and the range for pairwise comparisons was 0.14 to 0.52. With recognition factors, rater 1 was most strongly influenced by depth, rater 2 by shape and rater 3 by a possible combination of criteria. To reduce variability we suggest that narrow notches should be at least 15 dB in depth, and that broad notches should have a depth of 20 dB, with a recovery of at least 10 dB at the high end. Care should also be taken to elicit a sufficient history of noise exposure, and ensure that there are no other explanations for the notch.
听力缺口作为噪声暴露临床征象的特征
本研究通过要求三名临床医生在634名噪声暴露员工的听力图中识别缺口来调查听力学缺口识别的变异性。评估了评分者之间的一致性,并研究了三个缺口特征,频率,深度和形状(宽或窄缺口)作为识别因素。各评分者报告阳性的比例分别为0.26、0.49和0.68。“所有评分者”的一致性指数为0.45,两两比较的范围为0.14至0.52。在识别因素方面,评分1受深度影响最大,评分2受形状影响最大,评分3受可能的综合标准影响最大。为了减少变异性,我们建议窄陷波的深度至少为15db,宽陷波的深度应为20db,在高端至少有10db的恢复。还应注意引出足够的噪声暴露史,并确保没有其他原因造成缺口。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信