The Finnish speech in noise test for assessing sensorineural hearing loss

K. Laitakari, S. Uimonen
{"title":"The Finnish speech in noise test for assessing sensorineural hearing loss","authors":"K. Laitakari, S. Uimonen","doi":"10.1080/010503901300007416","DOIUrl":null,"url":null,"abstract":"A computerized adaptive Finnish speech in noise test was developed recently. As part of the test's evaluation process 172 patients with sensorineural hearing loss including 20 normally hearing subjects were measured using pure-tone audiometry, speech recognition threshold in noise (SRTN) test and conventional speech audiometry without background noise. As anticipated, sensorineural hearing loss yielded an elevation of SRTN although individual differences were considerable. The SRTN test was accurate as the absolute difference between individual repeated SRTNs was, on average, 1.5 dB (SD 1.5 dB) when the range of possible test values is from approximately -12 to +20 dB. On average, the learning effect was 0.5 dB.","PeriodicalId":76516,"journal":{"name":"Scandinavian audiology","volume":"53 1","pages":"165 - 166"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/010503901300007416","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/010503901300007416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A computerized adaptive Finnish speech in noise test was developed recently. As part of the test's evaluation process 172 patients with sensorineural hearing loss including 20 normally hearing subjects were measured using pure-tone audiometry, speech recognition threshold in noise (SRTN) test and conventional speech audiometry without background noise. As anticipated, sensorineural hearing loss yielded an elevation of SRTN although individual differences were considerable. The SRTN test was accurate as the absolute difference between individual repeated SRTNs was, on average, 1.5 dB (SD 1.5 dB) when the range of possible test values is from approximately -12 to +20 dB. On average, the learning effect was 0.5 dB.
芬兰语在噪音中的语音测试评估感音神经性听力损失
本文研制了一种计算机自适应芬兰语语音噪声测试方法。作为测试评估过程的一部分,172例感音神经性听力损失患者,其中20例听力正常,分别采用纯音测听法、语音识别噪声阈值(SRTN)测试和无背景噪声的常规语音测听法进行测试。正如预期的那样,感音神经性听力损失导致SRTN升高,尽管个体差异相当大。SRTN测试是准确的,因为当可能的测试值范围从大约-12到+20 dB时,个体重复SRTN之间的绝对差平均为1.5 dB (SD 1.5 dB)。平均而言,学习效果为0.5 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信