Neuroprotective Core Measure 2: Partnering with Families - Effects of a Weighted Maternally-Scented Parental Simulation Device on Premature Infants in Neonatal Intensive Care

Kendra Russell PhD, RN , Barbara Weaver MSN, RN (Doctoral Student) , Robert L. Vogel PhD
{"title":"Neuroprotective Core Measure 2: Partnering with Families - Effects of a Weighted Maternally-Scented Parental Simulation Device on Premature Infants in Neonatal Intensive Care","authors":"Kendra Russell PhD, RN ,&nbsp;Barbara Weaver MSN, RN (Doctoral Student) ,&nbsp;Robert L. Vogel PhD","doi":"10.1053/j.nainr.2015.06.005","DOIUrl":null,"url":null,"abstract":"<div><p><span>We sought to explore the effects of neuroprotective care with use of weighted maternally-scented parental simulation device on 24–38</span> <span>week gestation infants in a level III NICU. A sample of 45 infants was randomized into 1 of 4 groups. Infants in 2 of the groups were positioned with a weighted parental simulation device with and without maternal scent. Infants in a third group were placed in a soft nesting device with maternal scent, but without the weighted parental simulation device. Infants in the control group were given routine care without maternal scent or parental simulation device. Infants were observed and physiologic and behavioral data were recorded for a continuous 12-hour period of time. Infants positioned with a weighted maternally-scented parental simulation device demonstrated significantly more self-regulatory behaviors and were less likely to experience episodes of apnea (</span><em>HR</em> <!-->=<!--> <!-->9.828, <em>p</em> <!-->&lt;<!--> <!-->0.02) and bradycardia (<em>HR</em> <!-->=<!--> <!-->12.294, <em>p</em> <!-->&lt;<!--> <!-->0.006). Neuroprotective care using a weighted maternally-scented parental simulation device resulted in increased physiologic stability of premature and early term infants through the promotion of self-regulation seen by reduction of stressful behaviors, and decreased apnea, and bradycardia.</p></div>","PeriodicalId":87414,"journal":{"name":"Newborn and infant nursing reviews : NAINR","volume":"15 3","pages":"Pages 97-103"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1053/j.nainr.2015.06.005","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Newborn and infant nursing reviews : NAINR","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1527336915000847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

We sought to explore the effects of neuroprotective care with use of weighted maternally-scented parental simulation device on 24–38 week gestation infants in a level III NICU. A sample of 45 infants was randomized into 1 of 4 groups. Infants in 2 of the groups were positioned with a weighted parental simulation device with and without maternal scent. Infants in a third group were placed in a soft nesting device with maternal scent, but without the weighted parental simulation device. Infants in the control group were given routine care without maternal scent or parental simulation device. Infants were observed and physiologic and behavioral data were recorded for a continuous 12-hour period of time. Infants positioned with a weighted maternally-scented parental simulation device demonstrated significantly more self-regulatory behaviors and were less likely to experience episodes of apnea (HR = 9.828, p < 0.02) and bradycardia (HR = 12.294, p < 0.006). Neuroprotective care using a weighted maternally-scented parental simulation device resulted in increased physiologic stability of premature and early term infants through the promotion of self-regulation seen by reduction of stressful behaviors, and decreased apnea, and bradycardia.

神经保护核心措施2:与家庭合作-加权母亲气味父母模拟装置对新生儿重症监护早产儿的影响
我们试图探讨在III级新生儿重症监护室使用加权母味模拟装置进行神经保护护理对孕24-38周婴儿的影响。将45名婴儿随机分为4组中的1组。其中2组的婴儿被放置在有和没有母亲气味的加权父母模拟装置上。第三组婴儿被放置在带有母亲气味的柔软筑巢装置中,但没有加权的父母模拟装置。对照组给予常规护理,不使用母体气味或父母模拟装置。对婴儿进行连续12小时的观察,记录其生理和行为数据。放置加权母亲气味父母模拟装置的婴儿显着表现出更多的自我调节行为,并且不太可能经历呼吸暂停发作(HR = 9.828, p <0.02)和心动过缓(HR = 12.294, p <0.006)。神经保护护理使用加权母体气味父母模拟装置,通过促进自我调节,减少压力行为,减少呼吸暂停和心动过缓,从而增加早产儿和早月儿的生理稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信