The influence of sample dimensions on hydroxyl ion release from calcium hydroxide products.

P. Murray, P. Lumley, A. Smith, H. F. Ross
{"title":"The influence of sample dimensions on hydroxyl ion release from calcium hydroxide products.","authors":"P. Murray, P. Lumley, A. Smith, H. F. Ross","doi":"10.1034/J.1600-9657.2000.016006251.X","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to compare the rate of hydroxyl ion release from commercially available setting and non-setting calcium hydroxide products. The rate of hydroxyl ion release is important, as this has been suggested to be the main factor in the therapeutic activity of these products. In total, hydroxyl ion release was measured from 1104 samples of Dycal, Life, Calasept and Hypocal in solution using in vitro titration. The rate of hydroxyl ion release was measured for up to 14 days, using two sizes of sample surface area. The dimensions of the exposed sample surface area was found to be an important physical constraint to the hydroxyl ion release from non-setting calcium hydroxide products, whereas this was not found to be the case with setting products. The range in hydroxide activity between products was found to be 298%. In rank order of hydroxide ion release, from the most to the least active was: Hypocal, Calasept, Life and Dycal. The differences in the rate of hydroxyl ion release from these products may have some implications for their clinical applications. It is suggested that in cases where the oral healing responses have been poorer than expected, the size and seal of prepared cavities could have negatively influenced the therapeutic release of hydroxyl ions from non-setting calcium hydroxide products.","PeriodicalId":77113,"journal":{"name":"Endodontics & dental traumatology","volume":"114 1","pages":"251-7"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1034/J.1600-9657.2000.016006251.X","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endodontics & dental traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1034/J.1600-9657.2000.016006251.X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

The purpose of this study was to compare the rate of hydroxyl ion release from commercially available setting and non-setting calcium hydroxide products. The rate of hydroxyl ion release is important, as this has been suggested to be the main factor in the therapeutic activity of these products. In total, hydroxyl ion release was measured from 1104 samples of Dycal, Life, Calasept and Hypocal in solution using in vitro titration. The rate of hydroxyl ion release was measured for up to 14 days, using two sizes of sample surface area. The dimensions of the exposed sample surface area was found to be an important physical constraint to the hydroxyl ion release from non-setting calcium hydroxide products, whereas this was not found to be the case with setting products. The range in hydroxide activity between products was found to be 298%. In rank order of hydroxide ion release, from the most to the least active was: Hypocal, Calasept, Life and Dycal. The differences in the rate of hydroxyl ion release from these products may have some implications for their clinical applications. It is suggested that in cases where the oral healing responses have been poorer than expected, the size and seal of prepared cavities could have negatively influenced the therapeutic release of hydroxyl ions from non-setting calcium hydroxide products.
样品尺寸对氢氧化钙产物中羟基离子释放的影响。
本研究的目的是比较市售定型和非定型氢氧化钙产品的羟基离子释放速率。羟基离子释放的速率很重要,因为这被认为是这些产品治疗活性的主要因素。采用体外滴定法对1104个Dycal、Life、Calasept和Hypocal样品的羟基离子释放量进行了测定。使用两种尺寸的样品表面积,测量了长达14天的羟基离子释放率。暴露样品表面积的尺寸被发现是一个重要的物理限制,从非凝固的氢氧化钙产品的羟基离子释放,而这不是发现的情况下,凝固的产品。产物之间的氢氧化物活性差为298%。氢氧根离子释放活性从高到低依次为:Hypocal、Calasept、Life、Dycal。这些产物羟基离子释放速率的差异可能对它们的临床应用有一定的影响。这表明,在口腔愈合反应比预期差的情况下,制备的空腔的大小和密封可能会对非凝固氢氧化钙产物中羟基离子的治疗释放产生负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信