3 Tesla Magnetic Resonance Imaging (MRI)—Is it Ready for Prime Time Clinical Applications?

Jonathan W.K. Lee Ph.D. , Steven P. Shannon RT (R, MR)
{"title":"3 Tesla Magnetic Resonance Imaging (MRI)—Is it Ready for Prime Time Clinical Applications?","authors":"Jonathan W.K. Lee Ph.D. ,&nbsp;Steven P. Shannon RT (R, MR)","doi":"10.1016/S0820-5930(09)60258-9","DOIUrl":null,"url":null,"abstract":"<div><p>Magnetic resonance imaging (MRI) has advanced as one of the major tools for diagnostic imaging. The current benchmark in clinical imaging continues to be 1.5 T scanners. This review article examines if 3 T MRI is ready for prime time clinical applications. In the first part of the article, the history of clinical scanners will be discussed, including the 3 T development. The focus will then shift to the challenges and opportunities that 3 T's increased field strength brings. Special safety considerations and the technical requirements will be described, as well as a description of specific applications, along with the benefits and challenges at 3 T. The final sections will focus on a summary of optimization strategies and the importance of understanding the differences in imaging at 3 T.</p></div>","PeriodicalId":79737,"journal":{"name":"The Canadian journal of medical radiation technology","volume":"38 4","pages":"Pages 37-50"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0820-5930(09)60258-9","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Canadian journal of medical radiation technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0820593009602589","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Magnetic resonance imaging (MRI) has advanced as one of the major tools for diagnostic imaging. The current benchmark in clinical imaging continues to be 1.5 T scanners. This review article examines if 3 T MRI is ready for prime time clinical applications. In the first part of the article, the history of clinical scanners will be discussed, including the 3 T development. The focus will then shift to the challenges and opportunities that 3 T's increased field strength brings. Special safety considerations and the technical requirements will be described, as well as a description of specific applications, along with the benefits and challenges at 3 T. The final sections will focus on a summary of optimization strategies and the importance of understanding the differences in imaging at 3 T.

3特斯拉磁共振成像(MRI) -准备好黄金时间临床应用了吗?
磁共振成像(MRI)已成为诊断成像的主要工具之一。目前临床成像的基准仍然是1.5 T扫描仪。这篇综述文章探讨了3t MRI是否已经做好了临床应用的准备。在文章的第一部分,将讨论临床扫描仪的历史,包括3t的发展。然后,重点将转移到3t增强的现场力量带来的挑战和机遇上。特别的安全考虑和技术要求将被描述,以及特定应用的描述,以及3t成像的优势和挑战。最后部分将重点介绍优化策略的总结和理解3t成像差异的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信