{"title":"MRI and Patient Safety","authors":"Ni-orn Consiglio RTR, RTMR, PgD(MRT)","doi":"10.1016/S0820-5930(09)60130-4","DOIUrl":null,"url":null,"abstract":"<div><p>\n</p><ul><li><span>•</span><span><p>To identify and explain potential health risks in the MR environment</p></span></li><li><span>•</span><span><p>To discuss patient management related to MR procedures and safety</p></span></li></ul></div><div><h3>Abstract</h3><p>With the increasing use of MRI, there are increasing numbers of medical personnel involved with MR procedures. The purpose of this article is to promote MR safety among health care professionals. The information was gathered at Nanaimo Regional General Hospital, Nanaimo, BC. Although MRI is non-invasive and is free of ionizing radiation, there are health effects associated with this imaging modality even when it is sitting idle. The electromagnetic fields that are used in MRI induce electromagnetic forces and electrical current, which can pose health risks to the patients. Therefore, patient management related to MR procedures must be conducted with an understanding of and respect for this unique environment. To ensure patient safety, MR technologists and medical staff involved in MR studies must follow established safety policies and guidelines.</p></div><div><h3>Objectifs</h3><p>\n</p><ul><li><span>•</span><span><p>Préciser et expliquer les risques éventuels pour la santé relatifs à un environnement de radiation médicale</p></span></li><li><span>•</span><span><p>Examiner la prise en charge du patient en relation avec les procédures et la sécurité afférentes à la radiation médicale</p></span></li></ul></div><div><h3>Résumé</h3><p>Avec l'utilisation accrue de l'IRM, un nombre croissant de membres du personnel médical est concerné par les procédures de radiation médicale. L'objectif de cet article consiste à favoriser la sécurité des professionnels de la santé. L'information présentée provient du Nanaimo Regional General Hospital, de Nanaimo en Colombie-Britannique. L'IRM est non invasive et ne produit pas de rayonnement ionisant, mais des effets sur la santé sont associés à ce mode d'imagerie même lorsqu'il est au repos. Les champs électromagnétiques utilisés par l'IRM produisent des forces électromagnétiques et du courant électrique, lesquels peuvent constituer des risques pour la santé des patients. Par conséquent, la prise en charge du patient en relation avec les procédures de radiation médicale doit s'effectuer dans la compréhension et le respect de cet environnement particulier. Afin d'assurer la sécurité du patient, les technologues en radiation médicale et le personnel médical qui participent aux études sur la radiation médicale doivent respecter les politiques et les directives établies en matière de sécurité.</p></div>","PeriodicalId":79737,"journal":{"name":"The Canadian journal of medical radiation technology","volume":"37 2","pages":"Pages 5-9"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0820-5930(09)60130-4","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Canadian journal of medical radiation technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0820593009601304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
•
To identify and explain potential health risks in the MR environment
•
To discuss patient management related to MR procedures and safety
Abstract
With the increasing use of MRI, there are increasing numbers of medical personnel involved with MR procedures. The purpose of this article is to promote MR safety among health care professionals. The information was gathered at Nanaimo Regional General Hospital, Nanaimo, BC. Although MRI is non-invasive and is free of ionizing radiation, there are health effects associated with this imaging modality even when it is sitting idle. The electromagnetic fields that are used in MRI induce electromagnetic forces and electrical current, which can pose health risks to the patients. Therefore, patient management related to MR procedures must be conducted with an understanding of and respect for this unique environment. To ensure patient safety, MR technologists and medical staff involved in MR studies must follow established safety policies and guidelines.
Objectifs
•
Préciser et expliquer les risques éventuels pour la santé relatifs à un environnement de radiation médicale
•
Examiner la prise en charge du patient en relation avec les procédures et la sécurité afférentes à la radiation médicale
Résumé
Avec l'utilisation accrue de l'IRM, un nombre croissant de membres du personnel médical est concerné par les procédures de radiation médicale. L'objectif de cet article consiste à favoriser la sécurité des professionnels de la santé. L'information présentée provient du Nanaimo Regional General Hospital, de Nanaimo en Colombie-Britannique. L'IRM est non invasive et ne produit pas de rayonnement ionisant, mais des effets sur la santé sont associés à ce mode d'imagerie même lorsqu'il est au repos. Les champs électromagnétiques utilisés par l'IRM produisent des forces électromagnétiques et du courant électrique, lesquels peuvent constituer des risques pour la santé des patients. Par conséquent, la prise en charge du patient en relation avec les procédures de radiation médicale doit s'effectuer dans la compréhension et le respect de cet environnement particulier. Afin d'assurer la sécurité du patient, les technologues en radiation médicale et le personnel médical qui participent aux études sur la radiation médicale doivent respecter les politiques et les directives établies en matière de sécurité.