{"title":"Amperometric enzyme biosensors based on optimised electron-transfer pathways and non-manual immobilisation procedures","authors":"Wolfgang Schuhmann","doi":"10.1016/S1389-0352(01)00058-7","DOIUrl":null,"url":null,"abstract":"<div><p>Development of reagentless biosensors implies the tight and functional immobilisation of biological recognition elements on transducer surfaces. Specifically, in the case of amperometric enzyme electrodes, electron-transfer pathways between the immobilised redox protein and the electrode surface have to be established allowing a fast electron transfer concomitantly avoiding free-diffusing redox species. Based on the specific nature of different redox proteins and non-manual immobilisation procedures possible biosensor designs are discussed, namely biosensors based on (i) direct electron transfer between redox proteins and electrodes modified with self-assembled monolayers; (ii) anisotropic orientation of redox proteins at monolayer-modified electrodes; (iii) electron-transfer cascades via redox hydrogels; and (iv) electron-transfer via conducting polymers.</p></div>","PeriodicalId":101090,"journal":{"name":"Reviews in Molecular Biotechnology","volume":"82 4","pages":"Pages 425-441"},"PeriodicalIF":0.0000,"publicationDate":"2002-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1389-0352(01)00058-7","citationCount":"149","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reviews in Molecular Biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1389035201000587","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 149
Abstract
Development of reagentless biosensors implies the tight and functional immobilisation of biological recognition elements on transducer surfaces. Specifically, in the case of amperometric enzyme electrodes, electron-transfer pathways between the immobilised redox protein and the electrode surface have to be established allowing a fast electron transfer concomitantly avoiding free-diffusing redox species. Based on the specific nature of different redox proteins and non-manual immobilisation procedures possible biosensor designs are discussed, namely biosensors based on (i) direct electron transfer between redox proteins and electrodes modified with self-assembled monolayers; (ii) anisotropic orientation of redox proteins at monolayer-modified electrodes; (iii) electron-transfer cascades via redox hydrogels; and (iv) electron-transfer via conducting polymers.