Mohammed Chaudry MD, Matthew J. Dougherty MD, Douglas Troutman DO, Keith D. Calligaro MD
{"title":"Use of a hybrid polytetrafluoroethylene stent graft for iliofemoral bypass in the setting of femoral blow-out","authors":"Mohammed Chaudry MD, Matthew J. Dougherty MD, Douglas Troutman DO, Keith D. Calligaro MD","doi":"10.1016/j.jvsc.2015.03.011","DOIUrl":null,"url":null,"abstract":"<div><p>Revascularization in the setting of anastomotic “blow-out” in the groin is a technically demanding and morbid undertaking, often mandating transabdominal or retroperitoneal exposure of the iliac artery for proximal control or anastomosis, or both. The Gore Hybrid Vascular Graft (W. L. Gore and Associates Inc, Flagstaff, Ariz) is an expanded polytetrafluoroethylene graft with an external nitinol stent on one end designed for remote venous implantation for proximal axillary vein dialysis access outflow. We recently used this device to treat femoral anastomotic disruptions in two postoperative patients.</p></div>","PeriodicalId":91348,"journal":{"name":"Journal of vascular surgery cases","volume":"1 2","pages":"Pages 120-122"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jvsc.2015.03.011","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of vascular surgery cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352667X15000363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Revascularization in the setting of anastomotic “blow-out” in the groin is a technically demanding and morbid undertaking, often mandating transabdominal or retroperitoneal exposure of the iliac artery for proximal control or anastomosis, or both. The Gore Hybrid Vascular Graft (W. L. Gore and Associates Inc, Flagstaff, Ariz) is an expanded polytetrafluoroethylene graft with an external nitinol stent on one end designed for remote venous implantation for proximal axillary vein dialysis access outflow. We recently used this device to treat femoral anastomotic disruptions in two postoperative patients.
腹股沟吻合口“爆裂”情况下的血运重建术是一项技术要求高且病态的工作,通常需要经腹或腹膜后暴露髂动脉进行近端控制或吻合,或两者兼而有之。Gore混合型血管移植物(W. L. Gore and Associates Inc ., Flagstaff, arizona)是一种带有一端外置镍钛诺支架的膨化聚四氟乙烯移植物,设计用于近端腋窝静脉透析流出通道的远端静脉植入。我们最近使用该装置治疗了两例术后患者的股骨吻合口破裂。