Inadvertent Descemet membrane detachment after intracameral injection of high-viscosity sodium hyaluronate

Q4 Medicine
Yishay Weill MD, Koby Brosh MD, Joel Hanhart MD, Ben-Zion Silverstone, Yaakov Rozenman MD
{"title":"Inadvertent Descemet membrane detachment after intracameral injection of high-viscosity sodium hyaluronate","authors":"Yishay Weill MD,&nbsp;Koby Brosh MD,&nbsp;Joel Hanhart MD,&nbsp;Ben-Zion Silverstone,&nbsp;Yaakov Rozenman MD","doi":"10.1016/j.jcro.2017.10.004","DOIUrl":null,"url":null,"abstract":"<div><p><span>A patient developed extensive Descemet membrane<span><span><span><span> detachment after intracameral injection of a high-viscosity sodium hyaluronate </span>ophthalmic viscosurgical device (OVD) (sodium hyaluronate 2.3% [Healon5]). The patient had developed </span>anterior chamber shallowing after an Ex-Press shunt procedure. In an attempt to reform the anterior chamber, the OVD was administered intracamerally. However, during the procedure, a substantial amount of the material was injected accidentally just anterior to Descemet membrane. As a result, a large central Descemet membrane detachment was observed, accompanied by </span>corneal endothelium contact with the anterior surface of the intraocular lens. Two attempts to surgically evacuate the OVD were only partially successful. Conservative management resulted in the return of </span></span>visual acuity<span> to baseline, complete absorption of the OVD, and total reattachment of Descemet membrane. These findings were confirmed by long-term follow-up using anterior segment optical coherence tomography.</span></p></div>","PeriodicalId":14598,"journal":{"name":"JCRS Online Case Reports","volume":"6 1","pages":"Pages 4-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jcro.2017.10.004","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JCRS Online Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214167717300297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

A patient developed extensive Descemet membrane detachment after intracameral injection of a high-viscosity sodium hyaluronate ophthalmic viscosurgical device (OVD) (sodium hyaluronate 2.3% [Healon5]). The patient had developed anterior chamber shallowing after an Ex-Press shunt procedure. In an attempt to reform the anterior chamber, the OVD was administered intracamerally. However, during the procedure, a substantial amount of the material was injected accidentally just anterior to Descemet membrane. As a result, a large central Descemet membrane detachment was observed, accompanied by corneal endothelium contact with the anterior surface of the intraocular lens. Two attempts to surgically evacuate the OVD were only partially successful. Conservative management resulted in the return of visual acuity to baseline, complete absorption of the OVD, and total reattachment of Descemet membrane. These findings were confirmed by long-term follow-up using anterior segment optical coherence tomography.

在蝶腔内注射高粘度透明质酸钠后,无意中导致蝶膜脱离
1例患者在巩膜内注射高粘度透明质酸钠眼科粘胶手术装置(OVD)(透明质酸钠2.3% [Healon5])后出现广泛的Descemet膜脱离。患者在体外压分流术后前房变浅。在试图改革前房,OVD是施用内窥镜。然而,在手术过程中,大量的材料被意外注射到Descemet膜的前部。结果,观察到大面积的中央Descemet膜脱离,并伴有角膜内皮与人工晶状体前表面接触。两次手术摘除外阴的尝试仅部分成功。保守治疗使视力恢复到基线水平,OVD完全吸收,Descemet膜完全重新附着。这些发现得到了前段光学相干断层扫描长期随访的证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JCRS Online Case Reports
JCRS Online Case Reports Medicine-Ophthalmology
CiteScore
0.30
自引率
0.00%
发文量
22
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信