Integration of aqueous (micellar) two-phase systems on the proteins separation

IF 2.35
Filipa A. Vicente, João H. P. M. Santos, Inês M. M. Pereira, Cátia V. M. Gonçalves, Ana C. R. V. Dias, João A. P. Coutinho, Sónia P. M. Ventura
{"title":"Integration of aqueous (micellar) two-phase systems on the proteins separation","authors":"Filipa A. Vicente,&nbsp;João H. P. M. Santos,&nbsp;Inês M. M. Pereira,&nbsp;Cátia V. M. Gonçalves,&nbsp;Ana C. R. V. Dias,&nbsp;João A. P. Coutinho,&nbsp;Sónia P. M. Ventura","doi":"10.1186/s42480-019-0004-x","DOIUrl":null,"url":null,"abstract":"<p>A two-step approach combining an aqueous two-phase system (ATPS) and an aqueous micellar two-phase system (AMTPS), both based on the thermo-responsive copolymer Pluronic L-35, is here proposed for the purification of proteins and tested on the sequential separation of three model proteins, cytochrome c, ovalbumin and azocasein. Phase diagrams were established for the ATPS, as well as co-existence curves for the AMTPS. Then, by scanning and choosing the most promising systems, the separation of the three model proteins was performed. The aqueous systems based on Pluronic L-35 and potassium phosphate buffer (pH?=?6.6) proved to be the most selective platform to separate the proteins (S<sub>Azo/Cyt</sub>?=?1667; S<sub>Ova/Cyt</sub>?=?5.33 e S<sub>Azo/Ova</sub>?=?1676). The consecutive fractionation of these proteins as well as their isolation from the aqueous phases was proposed, envisaging the industrial application of this downstream strategy. The environmental impact of this downstream process was studied, considering the carbon footprint as the final output. The main contribution to the total carbon footprint comes from the ultrafiltration (~?49%) and the acid precipitation (~?33%) due to the energy consumption in the centrifugation. The ATPS step contributes to ~?17% while the AMTPS only accounts for 0.30% of the total carbon footprint.</p>","PeriodicalId":495,"journal":{"name":"BMC Chemical Engineering","volume":"1 1","pages":""},"PeriodicalIF":2.3500,"publicationDate":"2019-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s42480-019-0004-x","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemical Engineering","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1186/s42480-019-0004-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

A two-step approach combining an aqueous two-phase system (ATPS) and an aqueous micellar two-phase system (AMTPS), both based on the thermo-responsive copolymer Pluronic L-35, is here proposed for the purification of proteins and tested on the sequential separation of three model proteins, cytochrome c, ovalbumin and azocasein. Phase diagrams were established for the ATPS, as well as co-existence curves for the AMTPS. Then, by scanning and choosing the most promising systems, the separation of the three model proteins was performed. The aqueous systems based on Pluronic L-35 and potassium phosphate buffer (pH?=?6.6) proved to be the most selective platform to separate the proteins (SAzo/Cyt?=?1667; SOva/Cyt?=?5.33 e SAzo/Ova?=?1676). The consecutive fractionation of these proteins as well as their isolation from the aqueous phases was proposed, envisaging the industrial application of this downstream strategy. The environmental impact of this downstream process was studied, considering the carbon footprint as the final output. The main contribution to the total carbon footprint comes from the ultrafiltration (~?49%) and the acid precipitation (~?33%) due to the energy consumption in the centrifugation. The ATPS step contributes to ~?17% while the AMTPS only accounts for 0.30% of the total carbon footprint.

Abstract Image

水(胶束)两相体系在蛋白质分离上的集成
本文提出了一种基于热响应共聚物Pluronic L-35的水两相体系(ATPS)和水胶束两相体系(AMTPS)相结合的两步方法,用于蛋白质的纯化,并对细胞色素c、卵清蛋白和偶氮酪蛋白三种模型蛋白进行了顺序分离测试。建立了ATPS的相图和共存曲线。然后,通过扫描和选择最有希望的系统,进行三种模型蛋白的分离。以Pluronic L-35和磷酸钾缓冲液(pH = 6.6)为基础的水溶液体系被证明是分离蛋白质的最佳选择平台(SAzo/Cyt = 1667;SOva/Cyt?=?5.33 e SAzo/Ova?=?1676)。提出了这些蛋白质的连续分离以及从水相中分离的方法,设想了这种下游策略的工业应用。考虑碳足迹作为最终输出,研究了这一下游过程的环境影响。对总碳足迹的主要贡献来自超滤(~ 49%)和酸沉淀(~ 33%),这是由于离心过程中的能量消耗。ATPS步骤对~?17%,而AMTPS仅占总碳足迹的0.30%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信