Signal intensities and T 1 calculations in multiple-echo sequences with imperfect pulses

P. Kingsley
{"title":"Signal intensities and T 1 calculations in multiple-echo sequences with imperfect pulses","authors":"P. Kingsley","doi":"10.1002/(SICI)1099-0534(1999)11:1<29::AID-CMR2>3.3.CO;2-D","DOIUrl":null,"url":null,"abstract":"Formulas are derived for longitudinal magnetization in multiple-echo inversion recovery (IR), saturation recovery, and progressive saturation pulse sequences with imperfect pulses. The effects of imperfect pulses on the signal intensities and on the calculated T1 relaxation times are discussed. Relaxation data from all three methods can be fitted with an equation of the form: Signal intensity=[a+b exp(−TX/T1)]/[1+c exp(−TX/T1)], where TX is a variable delay time and the values of T1, a, b, and c are adjusted to optimize the fit. Only three parameters need to be fitted for progressive saturation with no echoes because b=−a. For modified fast IR (with constant repetition time TR), c=0 and a three-parameter fit suffices even if several non–steady-state signals are acquired and a range of flip angles is present within the sample. The advantages of the modified fast IR method for multiple-slice measurements of T1 in magnetic resonance imaging (MRI) are reviewed. Other applications of these formulas include estimating errors in T1 calculations, finding the flip angles (“Ernst angles”), echo spacing, and TR that maximize the signal-to-noise ratio in multiple-echo sequences, optimizing contrast between tissues in MRI, and determining how quickly a steady state is approached. ©1999 John Wiley & Sons, Inc. Concepts Magn Reson 11: 29–49, 1999","PeriodicalId":89665,"journal":{"name":"Concepts in magnetic resonance","volume":"27 2","pages":"29-49"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"52","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in magnetic resonance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(SICI)1099-0534(1999)11:1<29::AID-CMR2>3.3.CO;2-D","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 52

Abstract

Formulas are derived for longitudinal magnetization in multiple-echo inversion recovery (IR), saturation recovery, and progressive saturation pulse sequences with imperfect pulses. The effects of imperfect pulses on the signal intensities and on the calculated T1 relaxation times are discussed. Relaxation data from all three methods can be fitted with an equation of the form: Signal intensity=[a+b exp(−TX/T1)]/[1+c exp(−TX/T1)], where TX is a variable delay time and the values of T1, a, b, and c are adjusted to optimize the fit. Only three parameters need to be fitted for progressive saturation with no echoes because b=−a. For modified fast IR (with constant repetition time TR), c=0 and a three-parameter fit suffices even if several non–steady-state signals are acquired and a range of flip angles is present within the sample. The advantages of the modified fast IR method for multiple-slice measurements of T1 in magnetic resonance imaging (MRI) are reviewed. Other applications of these formulas include estimating errors in T1 calculations, finding the flip angles (“Ernst angles”), echo spacing, and TR that maximize the signal-to-noise ratio in multiple-echo sequences, optimizing contrast between tissues in MRI, and determining how quickly a steady state is approached. ©1999 John Wiley & Sons, Inc. Concepts Magn Reson 11: 29–49, 1999
不完全脉冲多重回波序列的信号强度和t1计算
推导了具有不完全脉冲的多回波反演恢复(IR)、饱和恢复和递进饱和脉冲序列纵向磁化的计算公式。讨论了不完全脉冲对信号强度和计算得到的T1弛豫时间的影响。三种方法得到的松弛数据可以用如下公式拟合:信号强度=[a+b exp(−TX/T1)]/[1+c exp(−TX/T1)],其中TX为可变延迟时间,调整T1、a、b和c的值以优化拟合。由于b= - a,对于无回波的渐进式饱和只需要拟合三个参数。对于改进的快速红外(具有恒定的重复时间TR),即使获得了几个非稳态信号并且样品内存在一定范围的翻转角度,c=0和三参数拟合也足够了。综述了改进的快速红外方法在磁共振成像(MRI)中多层测量T1的优点。这些公式的其他应用包括估计T1计算中的误差,寻找翻转角(“恩斯特角”),回波间隔,以及在多回波序列中最大化信噪比的TR,优化MRI中组织之间的对比度,以及确定接近稳定状态的速度。©1999 John Wiley & Sons, Inc概念管理,vol . 11: 29-49, 1999
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信