{"title":"Online grid measurement and ENS detection for PV inverter running on highly inductive grid","authors":"A.V. Timbus;R. Teodorescu;F. Blaabjerg;U. Borup","doi":"10.1109/LPEL.2004.834921","DOIUrl":null,"url":null,"abstract":"Photovoltaic (PV) and other sources of renewable energy are being used increasingly in grid-connected systems, for which stronger power quality requirements are being issued. Continuous grid monitoring should be considered so as to provide safe connections and disconnections from the grid. This letter gives an overview of the methods used for online grid measurement with PV inverters. Emphasis is placed on a method based on the injection of a noncharacteristic harmonic in the grid. Since this injection is regarded as a disturbance for the grid, different issues, i.e., the influence on total harmonic distortion (THD), the accuracy of line impedance measurement and the ENS (German abbreviation of Main Monitoring units with allocated Switching Devices) detection are studied. Laboratory results conducted on an existing PV inverter are presented to demonstrate the behavior of the PV inverter under different grid conditions. Some of the injection parameters are tuned in order to get an accurate measurement of line impedance.","PeriodicalId":100635,"journal":{"name":"IEEE Power Electronics Letters","volume":"2 3","pages":"77-82"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/LPEL.2004.834921","citationCount":"93","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Electronics Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/1359811/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 93

Abstract

Photovoltaic (PV) and other sources of renewable energy are being used increasingly in grid-connected systems, for which stronger power quality requirements are being issued. Continuous grid monitoring should be considered so as to provide safe connections and disconnections from the grid. This letter gives an overview of the methods used for online grid measurement with PV inverters. Emphasis is placed on a method based on the injection of a noncharacteristic harmonic in the grid. Since this injection is regarded as a disturbance for the grid, different issues, i.e., the influence on total harmonic distortion (THD), the accuracy of line impedance measurement and the ENS (German abbreviation of Main Monitoring units with allocated Switching Devices) detection are studied. Laboratory results conducted on an existing PV inverter are presented to demonstrate the behavior of the PV inverter under different grid conditions. Some of the injection parameters are tuned in order to get an accurate measurement of line impedance.
光伏逆变器运行在高感应电网上的在线电网测量和ENS检测
光伏(PV)和其他可再生能源越来越多地用于并网系统,对其提出了更高的电能质量要求。应考虑连续的电网监控,以便提供与电网的安全连接和断开连接。这封信概述了使用光伏逆变器进行在线电网测量的方法。重点介绍了一种基于在网格中注入非特征谐波的方法。由于这种注入被视为对电网的干扰,因此研究了不同的问题,即对总谐波失真(THD)的影响、线路阻抗测量的准确性和ENS(德语中带有分配开关设备的主监控单元的缩写)检测。在现有光伏逆变器上进行的实验室结果表明了光伏逆变器在不同电网条件下的行为。为了获得线路阻抗的精确测量,对一些注入参数进行了调谐。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信