{"title":"Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage","authors":"Jixing Sun, Yongzhi Fan, Jiyong Liu, Jindong Huo, Sibo Song, Yujian Ding, Yu Tian, Huili Wang, Nana Wu","doi":"10.1049/smt2.12153","DOIUrl":null,"url":null,"abstract":"<p>The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies the insulation deterioration of high-voltage equipment. To solve this problem, the vacuum breaker aging test method and the restrike characteristics are researched. A withstand voltage test platform of 40.5-kV vacuum circuit breaker was established to obtain the effects of the contact spacing and loop and inrush currents of vacuum circuit breaker on the number of restrike, the wavefront steepness of the breakdown voltage, and the breakdown duration. The number of restrike during the breaking of vacuum circuit breaker decreased and the duration of the repeated-breakdown arc increased with the increased contact spacing of vacuum circuit breaker. As the loop current of the test system increased, the number of restrike during the breaking of vacuum circuit breaker, the wavefront steepness of the breakdown voltage, and the duration of the restrike arc increased. As the inrush current amplitude increased during the closing of vacuum circuit breaker, the number of restrike and the duration of the repeated-breakdown arc during the breaking of vacuum circuit breaker increased. The results provide a theoretical basis and data support for the preventive test of 40.5-kV vacuum circuit breaker and the optimization of the withstand voltage test.</p>","PeriodicalId":54999,"journal":{"name":"Iet Science Measurement & Technology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/smt2.12153","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Science Measurement & Technology","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/smt2.12153","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies the insulation deterioration of high-voltage equipment. To solve this problem, the vacuum breaker aging test method and the restrike characteristics are researched. A withstand voltage test platform of 40.5-kV vacuum circuit breaker was established to obtain the effects of the contact spacing and loop and inrush currents of vacuum circuit breaker on the number of restrike, the wavefront steepness of the breakdown voltage, and the breakdown duration. The number of restrike during the breaking of vacuum circuit breaker decreased and the duration of the repeated-breakdown arc increased with the increased contact spacing of vacuum circuit breaker. As the loop current of the test system increased, the number of restrike during the breaking of vacuum circuit breaker, the wavefront steepness of the breakdown voltage, and the duration of the restrike arc increased. As the inrush current amplitude increased during the closing of vacuum circuit breaker, the number of restrike and the duration of the repeated-breakdown arc during the breaking of vacuum circuit breaker increased. The results provide a theoretical basis and data support for the preventive test of 40.5-kV vacuum circuit breaker and the optimization of the withstand voltage test.
期刊介绍:
IET Science, Measurement & Technology publishes papers in science, engineering and technology underpinning electronic and electrical engineering, nanotechnology and medical instrumentation.The emphasis of the journal is on theory, simulation methodologies and measurement techniques.
The major themes of the journal are:
- electromagnetism including electromagnetic theory, computational electromagnetics and EMC
- properties and applications of dielectric, magnetic, magneto-optic, piezoelectric materials down to the nanometre scale
- measurement and instrumentation including sensors, actuators, medical instrumentation, fundamentals of measurement including measurement standards, uncertainty, dissemination and calibration
Applications are welcome for illustrative purposes but the novelty and originality should focus on the proposed new methods.