{"title":"PWM methods to handle time delay in digital control of a UPS inverter","authors":"Heng Deng;R. Oruganti;D. Srinivasan","doi":"10.1109/LPEL.2004.842402","DOIUrl":null,"url":null,"abstract":"With the popularity of micro-processors, digital controllers are widely used in uninterruptible power supply (UPS) inverters. These digital control systems of UPS inverters require a time interval for sampling and computation, which sometimes affects the performance of inverters. In this paper, the problem of time delay in digital control of a UPS inverter is discussed. Then two novel pulsewidth modulation (PWM) methods, the two-polarity PWM method and the asymmetric PWM method, are proposed to handle the time-delay problem. Both of these PWM methods can achieve a wide range of duty ratio between 0.05-0.95, which is independent of inverter model. Furthermore, they are easy to implement using a digital micro-controller. Experimental results are presented in the paper to verify feasibility of the proposed PWM methods.","PeriodicalId":100635,"journal":{"name":"IEEE Power Electronics Letters","volume":"3 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2005-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/LPEL.2004.842402","citationCount":"69","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Electronics Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/1411770/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 69

Abstract

With the popularity of micro-processors, digital controllers are widely used in uninterruptible power supply (UPS) inverters. These digital control systems of UPS inverters require a time interval for sampling and computation, which sometimes affects the performance of inverters. In this paper, the problem of time delay in digital control of a UPS inverter is discussed. Then two novel pulsewidth modulation (PWM) methods, the two-polarity PWM method and the asymmetric PWM method, are proposed to handle the time-delay problem. Both of these PWM methods can achieve a wide range of duty ratio between 0.05-0.95, which is independent of inverter model. Furthermore, they are easy to implement using a digital micro-controller. Experimental results are presented in the paper to verify feasibility of the proposed PWM methods.
PWM方法处理UPS逆变器数字控制中的时间延迟
随着微处理器的普及,数字控制器被广泛应用于不间断电源(UPS)逆变器中。这些UPS逆变器的数字控制系统需要一定的采样和计算时间间隔,这有时会影响逆变器的性能。本文讨论了UPS逆变器数字控制中的时延问题。然后提出了两种新的脉宽调制(PWM)方法,即双极性PWM方法和非对称PWM方法来处理时滞问题。这两种PWM方法都可以实现0.05-0.95之间的宽占空比范围,这与逆变器模型无关。此外,它们易于使用数字微控制器来实现。文中给出了实验结果,验证了所提出的PWM方法的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信