{"title":"Application of posture-aware surgical tool assisted screw placement in orthopedic surgery of adolescent idiopathic scoliosis","authors":"Xiaonan Wu , Xinge Shi , Weiran Hu , Haohao Ma , Wensheng Liao , Yanzheng Gao","doi":"10.1016/j.isurg.2023.02.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>This study summarized and analyzed the clinical data, preoperative preparation, surgical process and postoperative recovery of patients, to explore the clinical effect of posture-aware surgical tool in adolescent idiopathic scoliosis orthopedic surgery.</p></div><div><h3>Methods</h3><p>This study demonstrated the whole process of using posture-aware surgical tools to assist the placement of screws in orthopedic surgery of adolescent idiopathic scoliosis. A 14-year-old and 8-month-old male with height 166 cm and weight 60 kg was diagnosed as Lenke type 1A adolescent idiopathic scoliosis. The preoperative X-ray films of the patients showed that the Cobb angle was 66°, CSVL-C7PL (Central Sacral Vertical Line -C7 plumb line) was 4 mm, SVA (sagittal vertical axis) was 5 mm. The operative fixed segment was T5∼L3 vertebral body. Renaissance and other three-dimensional software were utilized for screw placement angle, entry point and other related information before operation. The use of posture-aware surgical tools during surgery can accurately select screw length, type and screw placement angle, as planned by using three-dimensional software before operation.</p></div><div><h3>Results</h3><p>The entire operation process was smooth. The intraoperative blood loss was about 600 ml, and the operation time was about 445 min. A total of 18 screws were placed during the whole operation.The patient's Cobb Angle was 8.94°, CSVL-C7PL was 2 mm, and SVA was 3 mm on postoperative radiographs.</p></div><div><h3>Conclusion</h3><p>The implantation of pedicle screw assisted by posture-aware surgical tool is safe and effective with a smooth operation process and favorable patient outcomes.</p></div>","PeriodicalId":100683,"journal":{"name":"Intelligent Surgery","volume":"6 ","pages":"Pages 1-7"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intelligent Surgery","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666676623000030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
This study summarized and analyzed the clinical data, preoperative preparation, surgical process and postoperative recovery of patients, to explore the clinical effect of posture-aware surgical tool in adolescent idiopathic scoliosis orthopedic surgery.
Methods
This study demonstrated the whole process of using posture-aware surgical tools to assist the placement of screws in orthopedic surgery of adolescent idiopathic scoliosis. A 14-year-old and 8-month-old male with height 166 cm and weight 60 kg was diagnosed as Lenke type 1A adolescent idiopathic scoliosis. The preoperative X-ray films of the patients showed that the Cobb angle was 66°, CSVL-C7PL (Central Sacral Vertical Line -C7 plumb line) was 4 mm, SVA (sagittal vertical axis) was 5 mm. The operative fixed segment was T5∼L3 vertebral body. Renaissance and other three-dimensional software were utilized for screw placement angle, entry point and other related information before operation. The use of posture-aware surgical tools during surgery can accurately select screw length, type and screw placement angle, as planned by using three-dimensional software before operation.
Results
The entire operation process was smooth. The intraoperative blood loss was about 600 ml, and the operation time was about 445 min. A total of 18 screws were placed during the whole operation.The patient's Cobb Angle was 8.94°, CSVL-C7PL was 2 mm, and SVA was 3 mm on postoperative radiographs.
Conclusion
The implantation of pedicle screw assisted by posture-aware surgical tool is safe and effective with a smooth operation process and favorable patient outcomes.