Microhardness of different thicknesses of bulk fill composites.

IF 0.9 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
American journal of dentistry Pub Date : 2023-10-01
Ashton E Reno, Hoda S Ismail, Brian R Morrow, Anne E Hill, Franklin Garcia-Godoy
{"title":"Microhardness of different thicknesses of bulk fill composites.","authors":"Ashton E Reno,&nbsp;Hoda S Ismail,&nbsp;Brian R Morrow,&nbsp;Anne E Hill,&nbsp;Franklin Garcia-Godoy","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the microhardness values and bottom/top hardness ratios of different composites after being cured in 2 or 4 mm increments.</p><p><strong>Methods: </strong>Two bulk fill composites, methacrylate-based and ormocer-based, and one conventional composite were tested. 36 cylindrical discs were prepared (n=12/composite, with six for 2 mm, and six for 4 mm thickness) by pressing each composite into a mold between two glass slides covered by Mylar strips. The top and bottom surfaces of each sample were evaluated using a Buehler hardness tester for Knoop microhardness, with a 50 g static load applied for 10 seconds at three different locations of the central part of each sample. The bottom/top hardness ratio was calculated for each sample. The Knoop microhardness data and bottom/top ratio percentages were analyzed using two-way repeated measures ANOVA and Holm-Sidak post hoc test, with significance at P< 0.05.</p><p><strong>Results: </strong>The tested methacrylate-based bulk fill had the highest overall microhardness among the three tested composites. All three composite types showed a significant difference in microhardness between the top and bottom of the 4 mm discs. The bottom/top ratio percentages differed significantly for both tested bulk fill composites across different thicknesses. Both tested bulk fill materials had a bottom/top ratio of ≥ 80% at the deepest level of a 4 mm increment.</p><p><strong>Clinical significance: </strong>The type of material significantly affected both the bottom and top microhardness values under the experimental conditions used. While both tested bulk fill composites showed a decline in microhardness at the bottom of the 4 mm depth, they had clinically acceptable microhardness ratios at greater depths.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the microhardness values and bottom/top hardness ratios of different composites after being cured in 2 or 4 mm increments.

Methods: Two bulk fill composites, methacrylate-based and ormocer-based, and one conventional composite were tested. 36 cylindrical discs were prepared (n=12/composite, with six for 2 mm, and six for 4 mm thickness) by pressing each composite into a mold between two glass slides covered by Mylar strips. The top and bottom surfaces of each sample were evaluated using a Buehler hardness tester for Knoop microhardness, with a 50 g static load applied for 10 seconds at three different locations of the central part of each sample. The bottom/top hardness ratio was calculated for each sample. The Knoop microhardness data and bottom/top ratio percentages were analyzed using two-way repeated measures ANOVA and Holm-Sidak post hoc test, with significance at P< 0.05.

Results: The tested methacrylate-based bulk fill had the highest overall microhardness among the three tested composites. All three composite types showed a significant difference in microhardness between the top and bottom of the 4 mm discs. The bottom/top ratio percentages differed significantly for both tested bulk fill composites across different thicknesses. Both tested bulk fill materials had a bottom/top ratio of ≥ 80% at the deepest level of a 4 mm increment.

Clinical significance: The type of material significantly affected both the bottom and top microhardness values under the experimental conditions used. While both tested bulk fill composites showed a decline in microhardness at the bottom of the 4 mm depth, they had clinically acceptable microhardness ratios at greater depths.

不同厚度散装填充复合材料的显微硬度。
目的:比较不同复合材料在2或4 mm增量固化后的显微硬度值和底部/顶部硬度比。方法:测试两种本体填充复合材料,甲基丙烯酸酯基和ormocer基,以及一种常规复合材料。制备36个圆柱形圆盘(n=12/复合物,其中6个用于2mm,6个用于4mm厚度),通过将每个复合物压入由聚酯薄膜条覆盖的两个载玻片之间的模具中。使用Buehler努氏显微硬度计评估每个样品的顶面和底面,在每个样品中心部分的三个不同位置施加50g静载荷10秒。计算每个样品的底部/顶部硬度比。使用双向重复测量ANOVA和Holm-Sidak事后检验分析了努氏显微硬度数据和底部/顶部比率百分比,其显著性为P<0.05。结果:在三种测试的复合材料中,测试的甲基丙烯酸酯基大块填料具有最高的总显微硬度。所有三种复合材料类型在4mm圆盘的顶部和底部之间显示出显著的显微硬度差异。两种测试的散装填充复合材料在不同厚度下的底部/顶部比率差异显著。两种测试的散装填充材料在4 mm增量的最深处的底部/顶部比率均≥80%。临床意义:在所使用的实验条件下,材料类型显著影响底部和顶部显微硬度值。虽然两种测试的块体填充复合材料在4mm深度的底部显示出显微硬度下降,但它们在更大深度具有临床可接受的显微硬度比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
American journal of dentistry
American journal of dentistry 医学-牙科与口腔外科
CiteScore
2.40
自引率
7.10%
发文量
57
审稿时长
1 months
期刊介绍: The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信